background image



No power indication

No display on operators console

Power on – no motion

Material will not enter rolls

Material will not feed

Material feeds short

Material feeds long

Material camber

troUbleshootinG

Problem Cause Remedy

– Disconnect off.

– Blown fuse.

– Master button in.

– Program fault.

– Faulty wiring.

– Program fault.

– Drive fault.

– Program error.

– Feed roll adjusting mechanism

too close.

– Material too thick.

– Low roller force.

– Oily material.

– Program fault.

– Obstruction.

– Accel to fast.

– Low roller force.

– Oily material.

– Obstruction in path.

– High % max speed.

– Material slippery.

– Decell set too high.

– High roller force.

– Bad stock.

– Turn disconnect on.

– Check / replace fuse.

– Pull button out.

– Check lights on P.C.

– Check plug on console.

– Check lights on drive.

– Check lights on servo drive readout.

– Check parameters.

– Open adjustment mechanism.

– Check servo parameters.

– Raise roller pressure.

– Clean material.

– Check parameters.

– Check path.

– Lower accel speed.

– Raise roller pressure.

– Clean material.

– Check path.

– Lower % max feed speed.

– Lower % decell.

– Lower % decell.

– Lower roller pressure.

– Check stock at input for camber.