Pressing the F4 key, stops the automatic cycle and the main menu screen appears.
When the automatic screen is displayed, all keys except the F4 key are inactive. Every
time the press cycles and trips the feed switch, the feed will cycle once per the
parameters displayed on the screen. If the feed encounters excessive materail drag
while feeding or the material being moved encounters a restriction taht stops the
material forward movement then a servo fault can occur. If this happens then the
following screen is displayed.

A DRIVE FAULT HAS
OCCURED PLEASE CHECK
THE CONTROLS DISPLAY
FOR TYPE OF FAULT

If this screen is displayed then the control cabinet has to be opened and the Pac-Sci
drive has to be checked. To reset the fault, the master on-off switch has to be cycled
which will reset the controller. The material path should be checked for obstruction
and parrallelism to the die. If all this seems to be satisfactory and another fault occurs
the factory should be consulted.

MAIN MENU
F1=JOB # F2=MANUAL
F3=AUTOMATIC CYCLE
F4=REVIEW JOB PROGRAM
F4=JOB REVIEW

Pressing the F4 key will display the following screen. This screen asks for a sequence
number to be reviewed or modified. The program only allows reviewing of a sequence
in the job that is currently active. For an example, if job #1 had 4 sequences and
sequnce 1 was not functioning correctly then put ina 01 at this time.

REVIEW OR MODIFY SEQ
JOB NUMB=00 ENTER IN
THE SEQ=00 THEN
PRESS F4 TO CONTINUE

Pressing the F4 key will display the following screen.

JOB#=00 SEQUENCE#=00
FL=000.000 REPEAT=00
OUTPUTS=000 PILOTS=0
SPEED=000 ACCEL=000

The above screen displays the job number and the sequence that was selected. If all
that was needed was to look at the sequence to verify that it was correct then pressing
the F4 key will return you to the main menu. If there was a problem with this particular