The system is designed to operate on 120HZ 50/60 power. The unit is provided
with a power cord that is connected to a terminal strip located under the pallet
reel coil plate. The power is then distributed to the proper control panel. The
distributed power is circuit breaker protected and is intended as a power source
for the pallet reel and any additional Rapid Air accessory. Plug the main power
cord to any grounded 120 VAC, 20 amp receptacle.
PRE OPERATION CHECK
Before placing any material on the turn table, ensure that all functions are in the
correct mode for machine operations,
i.e.:
1.
Switch “OFF”
2.
RUN/STOP/JOG in the “STOP” position
3.
Spring loaded control arm has enough spring tension to return to the rest
position. (Type “B” arm). Counter balance set to return arm (Type “A” arm).
4.
Lock control box swivel mechanism into position
5.
Rotation direction switch agrees with the decoiling direction of the
material on the pallet that is ready to be loaded onto the pallet reel
6.
Loop range at maximum angle (#3 on thumbwheel)
7.
% speed at 30% to 50%. This may need to be increased or decreased to
keep up with press demand when the unit is in operation.
START UP AND RUN CHECK