CAUTION:

INSTALLATION

The installation of the valve is important for its
proper operation. Valves must be installed at
the system high points in the vertical position
with the inlet down. For pipeline service, a vault
with freeze protection, adequate screened
venting, and drainage should be provided.

During closure, some fluid discharge will occur
so vent lines should extend to an open drain
area in plant service. A shut-off valve should be
installed below the valve in the event servicing is
required.





VALVE CONSTRUCTION

The standard Air Release Valve body and cover
are cast iron. See the specific Materials List
submitted for the order if other than standard
cast iron construction. All internal components
are stainless steel with the exception of the
orifice button which is resilient. The general
details of construction are illustrated in Figure 2.
The body (1) is threaded for connection to the
pipeline. The seat (4) is threaded into the cast
cover (2).



















































TABLE 1. AIR RELEASE VALVE PARTS LIST























x



ITEM DESCRIPTION

MATERIAL


1 Body

Cast

Iron

2 Cover

Cast

Iron

3

Lever Frame*

Stainless Steel

4 Seat*

Stainless

Steel

5 Float*

Stainless

Steel

6 Gasket*

Non-Asbestos

7

Cover Bolt

Alloy Steel

8

Retaining Screw*

Stainless Steel

10

Float Arm*

Stainless Steel

11 Orifice

Button*

Buna-N

12

Pivot Pin*

Stainless Steel

13

Retaining Ring*

Stainless Steel

14 Pipe

Plug Iron

17

Float Retainer*

Stainless Steel

18

Lock Nut*

Stainless Steel

19

Link*

Stainless

Steel

21

Locating Pin

Stainless Steel

22

Orifice Button Arm*

Stainless Steel

30 Washer* Stainless

Steel

33

Clevis*

Stainless

Steel

34

Lock Washer*

Stainless Steel

*RECOMMENDED REPAIR PART KIT

Install valve with "INLET"
port down or leakage will
occur.

FIGURE 2. Compound Lever AIR RELEASE VALVE