HANDPUMP OPERATION: The Dashpot may be
equipped with a hand pump as shown in Figure 7.
The hand pump can be used to drive the valve
partially open using hydraulic oil pressure.

1. To open the Check Valve, close the round

Release Knob (turn clockwise 3 turns), insert the
pump handle into the pump, and stroke the
pump several times.


2. To close the Check Valve, open the Release

Knob (turn counterclockwise 3 turns) to release
the oil pressure.


Hand pump: Simplex Series P1000.















FIGURE 7. DASHPOT WITH HANDPUMP