OPERATING INSTRUCTIONS

THE PUMP: This pump is a totally enclosed, submersible dewatering unit. It is

powered by a 1/3 HP, 12 volt DC 30 AMP motor. Battery clips on the power cord allow

easy connection to any 12 volt vehicle battery.

SWITCHING: The on-off switch is located on the power cord.

CONNECTING TO BATTERY: When connecting the clips to a battery, arcing is

eliminated by keeping the on-off switch in the "off" position. Connect the red battery

clamp to the positive (+) battery terminal. Connect the black battery clamp to ground:

preferably on the vehicle’s engine to a solid, metallic, stationary point. The connection
should be at least 18 inches (480mm) from the battery.

IMPORTANT SAFETY

INFORMATION

Turn off before connecting battery

clamps to battery. Arcing could result.

DANGER

IMPORTANT

Read these safety warnings

and instructions in this

manual completely, before

installation and start-up of the pump. It is

the responsibility of the purchaser to retain

this manual for reference. Failure to comply

with the recommendations stated in this

manual will damage the pump, and void

factory warranty.

HOSE: Since the pump develops relatively low pressure, it is recommended

that non-collapsible hose be used for maximum pumping rates.

HOISTING & LOWERING: An eye at the top of the unit is provided for attaching

a line for hoisting or lowering.

Do not use power cable for handling unit.

TO OPERATE: Lower unit into liquid to be pumped and activate switch. Pump

can be run for a few minutes without liquid, however,

do not run completely dry for

extended periods. Damage to shaft seal may result.

RUNNING TIME: This unit draws about 30 amperes and can be operated about

1hour on a fully charged 55 AMP-hour battery and still permit starting of

vehicle under normal conditions. Caution should be used when running time

exceeds 30 or 40 minutes without engine running to recharge battery, particularly in

cold weather when battery efficiency is lowered. Battery size (AMP-hour rating) and

the use of other accessories such as lights and radios, etc., must be taken into

consideration for practical running periods without engine running.

OVERLOAD PROTECTION is provided by means of a 40 amp automatic reset

circuit breaker, located under top cover.

1. Make sure the vehicle and the

pump are not in contact during

connection.

2. Do not use power cable for

handling unit.

3. Do not run completely dry for

extended periods. Damage to shaft

seal may result.

DANGER

DANGER: Not for use with fluids

that have a flash point below 100°

F (38° C) [examples: gasoline, alcohol.]

Sparking could result in death.