Subsequently, when a button release command is

sent, the SpitFIRE completes the current

transmission and then it returns the appropriate

status.

Special scancodes are available to tell the

SpitFIRE to transmit IR message until told to

stop, or to send messages a fixed number of times.

The auto-repeat range is from 1 to 8 messages. A

setting of 0 tells the SpitFIRE to send the

message continuously until the button is released.

When the transmit N times feature is used, the

SpitFIRE will not return a status byte until the IR

transmission is completely sent (N times) so that

the system knows that the transmission is

complete.

The following is a list of scancodes that a system

can send to the SpitFIRE . Codes are in

hexadecimal and do not include the button-

pressed bit.

Code Code Function

Notes

0

00h

#0

1

01h

#1

2

02h

#2

3

03h

#3

4

04h

#4

5

05h

#5

6

06h

#6

7

07h

#7

8

08h

#8

9

09h

#9

10

0Ah ENTER

11

0Bh MUTE

12

0Ch VOL+

13

0Dh VOL-

14

0Eh CH+

15

0Fh CH-

16

10h

REWIND

17

11h

PLAY

18

12h

FF

19

13h

RECORD

20

14h

STOP

21

15h

PAUSE

22

16h

POWER

23

17h

RECALL

24

18h

TV/VCR

25

19h

DISPLAY

Code Code Function

Notes

26

1Ah REPEAT

27

1Bh RANDOM

28

1Ch MODE

29

1Dh DISC

30

1Eh SEL1

31

1Fh SEL2

32

20h

SEL3

33

21h

SEL4

34

22h

SEL5

35

23h

SEL6

36

24h

SEL7

37

25h

SEL8

38

26h

SEL9

39

27h

SEL10

40

28h

UP

41

29h

DOWN

42

2Ah LEFT

43

2Bh RIGHT

44

2Ch TRACK UP

45

2Dh TRACK DOWN

46

2Eh SKIP UP

47

2Fh SKIP DOWN

48

30h

INDEX UP

49

31h

INDEX DOWN

50

32h

TRACK

51

33h

GROUP

Advertising