Specification Summary

Tool Characteristics

Model

MSVe1-4.5 MSVi1-5.5

MSVi1-7.0

Compatible Tool

CRTe-1.0

CRTi2-5.5

CRTi3-7.0 CRTi2-8.63

CRTi4-7.0

Maximum Flow Rate

2,3

m

3

/min

1.7

1.7

2.5

4.4

Typical Pressure Drop

3,4

psi

92

92

73

53

Opening Pressure

psi

200

200

200

200

Closing Pressure

psi

180

180

180

180

Pressure Limit

5

psi

5,000

5,000

5,000

5,000

Maximum Pressure

End Load

ton

100

125

250

250

6

Maximum MSV Diameter

7

in

3.45

4.53

5.85

5.85

6

MSV Length

in

11.2

8

11.6

13.3

14.1

1 Patents pending.
2 Maximum flow rate is based on minimizing erosion rates when using typical fluids. Erosion rates may vary based on fluid

contents. Please regularly inspect MSV internals and wear surfaces indicated in operation manual.

3 Ratings provided represent design intent. These values may change pending outcome of design verification testing.
4 Value calculated based on 1200 kg/m

3

density, 60 s/L viscosity working fluid at maximum rated flow rate. Does not

include pressure drop induced by CRT or casing seal.

5 Circulation pressure is generally governed by packer cup pressure capacity. Pressure capacity may be less than

indicated if alternative seal arrangements are used or end load is exceeded.

6 Provision for 500 ton CRTi2-8.63 end load capacity is available upon request. Maximum MSV diameter will increase

to 6.33 in.

7 Does not consider CRT or casing seal assembly.
8 MSVe1-4.5 is housed entirely within CRTe body and does not add any length to CRT assembly.

Mudsaver Valve (MSV

)

1

Volant’s MSV adapts to the Casing Running Tool with either internal grip (CRTi

)

or external grip (CRTe

) architecture. The MSVi

is designed for internal grip

and MSVe

for external grip tools. Installed between the CRT and casing seal,

the MSV is designed to entirely stop fluid flow after fluid circulating or casing

running operations. The valve opens with applied pressure when circulating

begins, and closes when it is stopped. The MSV allows back flow and will not

trap pressure in the casing string.
The MSV has been designed to the same flow rate limit of each corresponding

CRTi and CRTe

3

.

MSVi1-7.0 installed

on CRTi4-7.0

Mudsaver Valve

(

MSVe1-4.5, MSVi1-5.5, MSVi1-7.0)

MSVe1-4.5, MSVi1-5.5, MSVi1-7.0 |

PAGE 1

MSVi1-7.0

Advertising
This manual is related to the following products: