Ross Controls NAMUR INTERFACE User Manual

Namur interface, New product introduction, Wash down service

Advertising
background image

NAMUR Interface

Wash Down Service

3/2 and 5/2

Solenoid Valve

Ambient/Media Temperature:

14 to 122° F (-10 to 50°C).
For temperatures below 40°F (4°C) air must be free
of water vapor to prevent formation of ice.
Flow Media: Filtered air. 5 micron recomended.
Flow: 0.25C

v

.

Pressure: 29 to 116 psig (2 to 8 bar).
Ports: 1/4 NPT Inlet.
Voltage: 24V DC 0.7 Watt.

110 - 120 V DC 50/60 Hz.
Standard: NEMA 4X.

STANDARD SPECIFICATIONS

• “Duck-bill” protected exhaust port(s):
- Limits wash down fluids from entering the valve
- Minimizes the collection point for contamination.
• Corrosion resistant epoxy powder coat.
• Solenoid Pilot – Low wattage, fast shifting, repeatable, long life.
• Patented Ball-poppet internals - Near zero internal leakage for

the life of the valve, self cleaning valve seats, sure shifting.

• Faster and more precise operation than a spool valve.
• 3/2 Normally Closed and 5/2 Function.

New Product

Introduction

APPLICATIONS:

FEATURES:

US Patent # 5,918,631

Designed for wash down application – minimum collection

point for contamination.
Ideal for food and beverage industries.

Process industries - Hot, cold, wet environments.

Function Model Number* Mounting Bolts Connection

3/2

3473D1904W

10-32

M12 Micro

3/2

3473D1900W

10-32

DIN 43650 form A

5/2

3476C1904W

10-32

M12 Micro

5/2

3476C1900W

10-32

DIN 43650 form A

* W= 24 VDC. For 110 VAC, replace “W” with a “Z”.
Note: 10-24 and M5 mounting bolts available upon request.

Model with DIN electrical connector shown.

A

B

C

Model with 3/2
port size shown.

Dimensions inches (mm)

Weight

Function

A

B

C

lb. (kg)

3/2

4.62 (117.4) 2.19 (55.50) 1.2 (30.5) 0.8 (0.3)

5/2

5.32 (135.2) 2.19 (55.50) 1.2 (30.5) 0.9 (0.4)

WARRANTY and

CAUTIONS

Standard ROSS cautions apply, available upon request or at

www.rosscontrols.com/pdfs/cautionswarranty.pdf.

ROSS EUROPA GmbH

Germany

Fax: 49-6103-74694

[email protected]

ROSS ASIA

®

K.K.

Japan

Fax: 81-427-78-7256

[email protected]

ROSS UK Ltd.

United Kingdom

Fax: 44-121-559-5309

[email protected]

ROSS SOUTH AMERICA Ltda.

Brazil

Fax: 55-11-4335-3888

[email protected]

ROSS CONTROLS

®

INDIA Pvt. Ltd.

India

Fax: 91-44-2625-8730

[email protected]

DIMAFLUID s.a.s.

France

Fax: 33-01-4945-6530

[email protected]

ROSS CONTROLS

(CHINA) Ltd.

China

Fax: 86-21-6915-7960

[email protected]

ROSS CONTROLS

®

U.S.A.

Customer Svs. 1-800-GET-ROSS

Technical Svs. 1-888-TEK-ROSS

www.rosscontrols.com

Printed in the U.S.A. – Rev. 8/08

© 2008, ROSS CONTROLS

®

. All Rights Reserved.

Form NPS008

Model with M12 Micro electrical connector shown.

1

4

3

2

M 12 Connector Pin Out

1 = N/C
2 = N/C
3 = BROWN (Positive)
4 = BLUE (Negative)