• Tightening the screws with too much

force can damage the LT unit’s plastic
case.

• The necessary torque is 0.5N

•m.

• Be sure to insert installation fasteners

in the recessed portion of a installation
fasteners hole. If the fasteners are not
correctly attached, the LT unit may shift
or fall out of the panel.

3.

Wiring to the DIO Connector

• Be sure to remove the DIO Connector

from the LT unit prior to starting wiring.
Failure to do so may cause an electric
shock.

„ Items Required to Wire Connectors

Screwdriver

Recommended type: 1891348-1 <Tyco Elec-
tronics AMP.>

If another manufacturer is used, be sure the
part has the following dimensions:

point depth: 1.5mm [0.06in.]

point width: 2.4mm [0.09in.]

Point shape should be DIN5264A, and meet
Security Standard DN EN60900.

Also, the screwdriver’s tip should be flat as
indicated in order to access the narrow hole
of the connector:

„ DIO Cable Specifications

„ Connecting the DIO Cable

(1) Insert a flathead screwdriver, at an angle,

into the tool insertion hole (square-
shaped hole) of the connector.

(2) When inserting the flathead screw driver,

be sure that it is perpendicular to the cen-
ter division wall.

• Make the insertion distance of the flathead

screwdriver approximately 4 mm. Insert-
ing forcefully may break the inside of the
connector and will a cause of contact
defect.
Also, do not turn the flathead screwdriver
while the tip is inside of the tool insertion
hole (square-shaped hole).

(3) The adjacent wire insertion hole (round-

shaped hole) will be in an open state.
With the flathead screwdriver still
inserted, insert the wire into the wire
insertion hole (round-shaped hole).

Insertion Slot Recess

Hook the fastener
on the Recess,

Panel

Installation Fastener

Hook

and secure the fastener
on the panel with a
screw.

LT

Panel

Completed View

Screwdriver Tip

Shape

DIO Cable
Diameter

AWG24 to 18
UL1015 or UL1007

Conductor
Type

Stranded Wire

*1

*1 If the Conductor’s end (individual) wires are

not twisted correctly, the end wires may either
short against each other, or against an
electrode.

Conductor
Length

7 mm
[0.28in]

Screwdriver

Wire

Wire insertion hole
(Round-shaped hole)

Tool insertion hole
(Square-shaped hole)