FIREBAR® Screw Plug Installation & Maintenance Manual

I&M NUMBER: 316-42-3-1

Page: 3

Date: 6/11/2008

Rev: 2.00

________________________________________________________________________________________________________________________________________________________________________________________________________________________

WATLOW IND.n # 6 INDUSTRIAL LOOP RD. n HANNIBAL MO, 63401n PHONE 573-221-2816 n FAX 573-221-3723

During installation of the heater it is important that special attention be given to the final orientation of the
element. The flat side of the element must be positioned vertically as shown in Figure #2. Maximum
advantages are realized when the element is within +/- 25° of vertical. Positions outside this range are
not recommended, and 90° from vertical should always be avoided.


Each plug is marked with "TOP" to help clarify the preferred orientation. For open tank heating, this
marking should normally be on top of the final plug position. If this is not practical, it may be positioned
on the bottom, which will also orient the flat element vertical.


If heater is being installed in customer supplied circulation tank, a FIREBAR® Circulation I&M manual
should be obtained from the factory to ensure safe installation of heater in tank. Failure to do this could
result in premature heater failure due to improper fluid flow over elements

SLUDGE

LIQUID LEVEL

2" MIN

FEMALE PIPE COUPLING TO MATCH
SCREW PLUG SIZE

HEATER REMOVAL

ALLOWANCE FOR

"X" POSITION

Figure # 1


TOP

25

25

CORRECT ORIENTATION

INCORRECT ORIENTATION

Remove terminal enclosure to see element position

Figure # 2