Watlow ind – Watlow WATROD Duct Heater (Module Only) User Manual

Page 6

Advertising
background image

WATLOW IND.

WATROD Duct Heater (module only) I& M Manual

I&M NUMBER: 316-42-16-1

Page: 6

Date: 6/11/2008

Rev: 2.00

_________________________________________________________________________________________________________________________________________________________________________________________________________________________
______

WATLOW IND.n # 6 INDUSTRIAL LOOP RD. n HANNIBAL MO, 63401n PHONE 314-221-2816 n FAX 314-221-3723

Split Washer

Allen Screw or
Self Tapping Screw

Heater Module

Duct

Optional
Housing

To install high limit thermocouple kit:
a)

Perform steps a - d above.

b)

Use a 11/32” drill to drill a pilot hole at the location depicted by the “+” mark shown on the flange

below.

Watlow Modular Duct Heater
PN XXXXXXXXXX
XXXX W, XXX V, XPH, XXXX

TOP

c)

Use a 1/8 NPT tap to thread the hole drilled in step b. Make certain that the hole being tapped

is perpendicular to the flange. If it is not perpendicular, electrical shorting may occur between the

compression fitting and the nearby electrical jumpers.

d)

Thread the lower portion of the compression fitting in the hole tapped above.

e)

Insert thermocouple through lower portion of compression fitting threaded into flange and through

hole in upper support bracket until transition fitting of thermocouple is bottomed out.

f)

Tighten upper portion of compression fitting to firmly hold thermocouple in place.

g)

Wrap thermocouple as shown in the diagram below about two times on a 2” diameter.

h)

Attach tip of thermocouple to mid section of element using the hose clamp provided. The tip of the

thermocouple should not be covered by the hose clamp, but should extend about 3/16” from the

hose

clamp.

i)

Pass heat shrink provided over thermocouple leads and compression fitting. Heat shrink sleeving so

that it adheres to the shape of the compression fitting and thermocouple.

Advertising