Understanding tr-08, Appendix b – ADTRAN 1202076L2 User Manual

Page 103

Advertising
background image

61202076L1-1

TSU 600 User Manual

B-1

Appendix B

Understanding TR-08

The TSU 600 chassis functions as a Remote Terminal in Digital Loop
Carrier

and as Integrated Digital Loop Carrier Systems as described in

TR-TSY 000008. The TSU 600 supports SLC96 framing, Mode I opera-
tion, ORB-13 and ORB-16 alarm formats, alarm reporting, and user-de-
finable BPV threshold detection rate.

A basic familiarity with DLC systems, IDLC systems, and TR-TSY-
000008 is assumed, but the following information will be useful:

•

All received TR-TSY-000008 specific alarms are reported locally
within the history feature of the TSU 600.

•

When the DISABLE ALARMS option is selected, no alarms will be
sent on the DLF, but received alarms will be reported locally in the
history.

•

Other alarms normally reported by the TSU 600 will also be placed
in history.

•

Each TSU 600 needs to be configured as the A SHELF, as it is provi-
sioned as a separate entity.

•

All alarms will refer to A SHELF when received from TSU 600.