15 ° c when /he is specified, Safe area hazardous area, Terminator – Yokogawa EJA115 User Manual

Page 5

Advertising
background image

( IV ) for /KN26

c. ATEX Type of Protection “n”

Model EJA Series differential, gauge, and absolute
pressure transmitters with optional code /KN26.

WARNING

When using a power supply not having a
nonincendive circuit, please pay attention not to
ignite in the surrounding flammable atmosphere.
In such a case, we recommend using wiring
metal conduit in order to prevent the ignition.

WARNING

• Electrostatic charge may cause an explosion

hazard. Avoid any action that cause the gen-
eration of electrostatic charge, such as rubbing
with a dry cloth on coating face of the product.

• Applicable standard: EN 60079-0:2009, EN60079-

15:2005

• Type of Protection and Marking Code:

Ex nL IIC T4 Gc

• Group: II
• Category: 3G
• Ambient Temperature: –30* to 60

°

C

*–15

°

C when /HE is specified

• Ambient humidity: 0 to 100%RH (No condensation)
• Enclosure: IP67

Note 1. Electrical Data

Ui = 32 Vdc
Ci = 3.52 nF
Li = 0

µ

H

Note 2. Installation

• All wiring shall comply with local installation

requirements. (refer to the installation diagram)

Safe Area

Hazardous Area

F0208.EPS

Terminator

Terminator

Field Instruments

EJA

Pressure

Transmitter

Field Instruments

Associated

Apparatus

ϩ

Ϫ

ϩ

Ϫ

ϩ

Ϫ

Vmax = 32 Vdc
Ci = 3.52 nF
Li = 0

␮

H

Note 3. Maintenance and Repair

• The instrument modification or parts replacement by

other than authorized representative of Yokogawa
Electric Corporation is prohibited and will void
Type of Protection “n”.

(V)

᭹

Tag plate for flameproof type

᭹

Tag plate for flameproof, intrinsically safe type,

type n protection, and Dust (for /KU22)

F0298.EPS

D

T65

Њ

C (Tamb.: 40

Њ

C), T85

Њ

C (Tamb.: 60

Њ

C),and T105

Њ

C (Tamb.: 80

Њ

C)

AFTER DE-ENERGIZING, DELAY 10 MINUTES BEFORE OPENING. WHEN THE
AMBIENT TEMP.

Ն

70

Њ

C, USE THE HEAT-RESISTING CABLES

Ն

90

Њ

C. SEE USER'S

MANUAL BEFORE USE. POTENTIAL ELECTROSTATIC CHARGING HAZARD.

SEE USER'S
MANUAL

Tamb.

Ϫ

30(

Ϫ

15) TO 60

Њ

C

TEMP.CLASS/MAX SURFACE TEMP. T6/T85

Њ

C T5/T100

Њ

C T4/T120

Њ

C

WARNING

D

, Ex tD A21 IP6X T85

Њ

C,T100

Њ

C,T120

Њ

C

ENCLOSURE:IP67

Tamb.

Ϫ

40(

Ϫ

15) TO

KU22

Tamb.

Ϫ

40(

Ϫ

15) TO 75

Њ

C(T6 and T4)

AFTER DE-ENERGIZING, DELAY 10 MINUTES BEFORE OPENING.
WHEN THE AMBIENT TEMP.

Ն

70

Њ

C, USE THE HEAT-RESISTING

CABLES

Ն

90

Њ

C. SEE USER'S MANUAL BEFORE USE.

Ϫ

40(

Ϫ

15) TO 80

Њ

C(T5)

CAUTION

KF21

᭹

Tag plate for flameproof, intrinsically safe type,

type n protection, and Dust (for /KU21)

D

T65

Њ

C (Tamb.: 40

Њ

C), T85

Њ

C (Tamb.: 60

Њ

C),and T105

Њ

C (Tamb.: 80

Њ

C)

AFTER DE-ENERGIZING, DELAY 10 MINUTES BEFORE OPENING.
WHEN THE AMBIENT TEMP.

Ն

70

Њ

C, USE THE HEAT-RESISTING

CABLES

Ն

90

Њ

C. SEE USER'S MANUAL BEFORE USE.

SEE USER'S
MANUAL

Tamb.

Ϫ

40(

Ϫ

15) TO 60

Њ

C

TEMP.CLASS/MAX SURFACE TEMP. T6/T85

Њ

C T5/T100

Њ

C T4/T120

Њ

C

CAUTION

D

, Ex tD A21 IP6X T85

Њ

C,T100

Њ

C,T120

Њ

C

ENCLOSURE:IP67

Tamb.

Ϫ

40(

Ϫ

15) TO

KU21

Gc

Advertising