Note 4. Operation

• Keep the “WARNING” label attached to the

transmitter.

WARNING: AFTER DE-ENERGIZING,

DELAY 5 MINUTES BEFORE OPENING.

WHEN THE AMBIENT TEMP.≥65°C, USE

HEAT-RESISTING CABLES≥90°C.

• Take care not to generate mechanical

sparking when accessing the instrument and

peripheral devices in hazardous location.

Note 5. Maintenance and Repair

• The instrument modification or part

replacement by other than an authorized

representative of Yokogawa Electric

Corporation is prohibited and will void KEMA

Flameproof Certification.

(2) Electrical Connection
A mark indicating the electrical connection type is

stamped near the electrical connection port. These

marks are as follows.

F0210r.ai

Location of the mark

Screw Size

Marking

ISO M20 × 1.5 female
ANSI 1/2 NPT female

M

A or

W

N or

(3) Installation

WARNING

• All wiring shall comply with local installation

requirements and the local electrical code.

• There is no need for a conduit seal in

Division 1 and Division 2 hazardous

locations because this product is sealed at

the factory.

(4) Operation

WARNING

• OPEN CIRCUIT BEFORE REMOVING

COVER. INSTALL IN ACCORDANCE WITH

THIS USER’S MANUAL

• Take care not to generate mechanical

sparking when accessing the instrument and

peripheral devices in a hazardous location.

(5) Maintenance and Repair

WARNING

The instrument modification or part replacement

by other than an authorized Representative of

Yokogawa Electric Corporation is prohibited and

will void the certification.

(6) Name Plate

Name plate

Tag plate for flameproof type

Tag plate for intrinsically safe type

Tag plate for intrinsically safe type for EJX90A

F0211r.ai

D

D

AFTER DE-ENERGIZING, DELAY 5 MINUTES

BEFORE OPENING.

WHEN THE AMBIENT TEMP. ≥ 65°C,

USE THE HEAT-RESISTING CABLES ≥ 90°C

No. KEMA 07ATEX0109

Ex d IIC T6...T4, Ex tD A21, IP6X

Enlcosure : IP66, IP67

TEMP. CLASS T6 T5 T4

MAX PROCESS TEMP.(Tp.) 85 100 120 °C

Tamb. -50(-15) to 75 80 75 °C

T85°C(Tamb.:40°C, Tp.:80°C),T100°C(Tamb.:60°C, Tp.:100°C),

T120°C(Tamb.:80°C, Tp.:120°C) Min.Tamb.:-40(-15) °C(for Dust)

WARNING

No. KEMA 04ATEX1116 X

EEx ia IIB/IIC T4 Tamb.:-40(-15) to 60°C

MAX PROCESS TEMP.(Tp.):120°C

T85°C(Tp.:80°C), T100°C(Tp.:100°C), T120°C(Tp.:120°C)

Enclosure: IP66 and IP67

FISCO Field device(IIC) FISCO Field device(IIB) Entity Parameters

Ui=17.5V

Ui=17.5V

Ui=24V

Ii=380mA

Ii=460mA

Ii=250mA

Pi=5.32W

Pi=5.32W

Pi=1.2W

Ci=1.76nF

Ci=1.76nF

Ci=1.76nF

Li=0µH

Li=0µH

Li=0µH

D

No. KEMA 06ATEX0278 X

EEx ia IIB/IIC T4 Tamb.:-40(-15) to 60ºC

MAX PROCESS TEMP.(Tp.):120ºC

T85ºC(Tp.:80ºC), T100ºC(Tp.:100ºC), T120ºC(Tp.:120ºC)

Enclosure: IP66 and IP67

FISCO Field device(IIC) FISCO Field device(IIB) Entity Parameters

Ui=17.5V

Ui=17.5V

Ui=24V

Ii=380mA

Ii=460mA

Ii=250mA

Pi=5.32W

Pi=5.32W

Pi=1.2W

Ci=1.76nF

Ci=1.76nF

Ci=1.76nF

Li=0µH

Li=0µH

Li=0µH