Rooftop packaged unit with evaporative cooling, Table 2b – Sterling EV User Manual

Page 5

Advertising
background image

–

5

–

Rooftop Packaged Unit

with Evaporative Cooling

Figure 4 - Natural Vent Rooftop Unit with Evaporative Cooler (with Supply Plenum)

A.G.A.

C.G.A.

GAS INLET

CAPACITY

A C D D *F G

▲

J L Q R §U NAT

LP

10

32-7/8

12

11

20-11/16 19-3/8 31-1/16

24

103-3/8

NA

NA

98-1/4

1/2

1/2

(835) (305) (279) (525) (492) (789) (610) (2626)

(2496)

15

32-7/8

21-1/2

16

25-3/16

23-1/2 31-1/16

24

103-3/8

NA

NA

98-1/4

1/2

1/2

(835) (546) (406) (640) (597) (789) (610) (2626)

(2496)

20

43-7/8

23-1/2

16

25-3/16

26-1/4 42-1/16

35

103-3/8

NA

NA

98-1/4

1/2

1/2

(1114) (597) (406) (640) (667) (1068) (889) (2626)

(2496)

25

43-7/8

23-1/2

16

25-3/16

34-1/2 42-1/16

35

103-3/8

NA

NA

98-1/4

3/4

1/2 OR 3/4

(1114) (597) (406) (640) (876) (1068) (889) (2626)

(2496)

30

54-7/8

26

17-1/2 26-11/16 37-1/4 53-1/16

46

103-3/8

NA

NA

98-1/4

3/4

1/2 OR 3/4

(1394) (660) (445) (678) (946) (1348)

(1168)

(2626)

(2496)

35

54-7/8

26

17-1/2 26-11/16 45-1/2 53-1/16

46

103-3/8

NA

NA

98-1/4

3/4

1/2 OR 3/4

(1394) (660) (445) (678) (1156) (1348) (1168) (2626)

(2496)

40

60-3/8

26

17-1/2 26-11/16

51

58-9/16

51-1/2 103-3/8

NA

NA

98-1/4

3/4

1/2 OR 3/4

(1534) (660) (445) (678) (1295) (1487) (1308) (2626)

(2496)

50

43-7/8

23-1/2

16

25-3/16

34-1/2 42-1/16

35

129-5/16 58-3/4

38-5/8 124-1/4

3/4

1/2 OR 3/4

(1114) (597) (406) (640) (876) (1068) (889) (3285) (1492) (981) (3156)

60

54-7/8

26

17-1/2 26-11/16 37-1/4 53-1/16

46

129-5/16 58-3/4

38-5/8 124-1/4

3/4

1/2 OR 3/4

(1394) (660) (445) (678) (946) (1348) (1168) (3285) (1492) (981) (3156)

70

54-7/8

26

17-1/2 26-11/16 45-1/2 53-1/16

46

129-5/16 58-3/4

38-5/8 124-1/4

3/4

1/2 OR 3/4

(1394) (660) (445) (678) (1156) (1348) (1168) (3285) (1492) (981) (3156)

80

60-3/8

26

17-1/2 26-11/16

51

58-9/16

51-1/2 129-5/16 58-3/4

38-5/8 124-1/4

3/4

1/2 OR 3/4

(1534) (660) (445) (678) (1295) (1487) (1308) (3285) (1492) (981) (3156)

NOTE: REFER TO UNIT SUBMITTALS FOR MORE SPECIFICATIONS/UNIT ARRANGEMENTS.

DIMENSIONS ARE IN INCHES, DIMENSIONS IN PARENTHESIS ARE IN MILLIMETERS.
* “F” DIMENSION IS THE RECOMMENDED CLEARANCE TO SERVICE THE BURNER DRAWER(S).

▲

“J” DIMENSION IS AN OUTSIDE DIMENSION FOR RETURN AIR DAMPERS.

▲

“J” DIMENSION IS ALSO AN INSIDE DIMENSION FOR SUPPLY AIR (WITHOUT DAMPER).

§ “U” ALL DIMENSIONS ARE TABULATED FOR ROOFTOP ARRANGEMENTS C & E PER CAPACITIES 10 THROUGH 80 ACCORDINGLY

(CAPACITIES 50/80 ARE SHOWN PICTORIALLY).

NATURAL VENT UNIT DIMENSIONS SHOWN ABOVE; FOR POWER VENT DIMENSIONS, CONTACT CUSTOMER SERVICE FOR POWER
VENT

UNIT

SUBMITTAL

SHEETS.

Table 2B

J Inside

Supply Opening

1-5/16" (33) Typ.
Anchor Hole
Location

5"

(127)

A

C (Typ.) Sq.

*

F

CL

D

39"

(991)

G

1" (25)

Curb Cap

D4165
T4160CE

5/8" (16) Typ.
Anchor Hole
Location

6-1/16"

(154)

Vent Caps
Are Shipped
In Separate
Cartons

Gas
Connection

6-1/16"

(154)

Evaporative
Cooler

18-7/8" (479)

x J Typ.

Inside

Opening

34-3/4"

(883)

26"

(660)

18-7/8" (479)

x J Typ.

O.S. Damper

Opening

6-1/2"

(165)

3-9/16"

(90)

Lifting
Brackets

Electrical
Connections

Outside

§ R

§ Q

§ L

§ U

26"

(660)

26"

(660)

36"

(914)