Fill charge cylinder – MAHLE RTI Matco AC880 User Manual
Page 6

Page 5
x
x
x
x x
x
x
x x
x
x
x EXTREMELY IMPORTANT x
x
x
x x
x
x
x x
x
x
x
Always connect Yellow Hose (15) to Cylinder (14) first and then connect
other end of hose with anti-blowback valve to Fill Port (13) on AC880.
W E I G H T =
X X . X
L B
A U T O M A T I C
?
5
>>>>
W E I G H T =
X X . X
L B
F I L L
C Y L I N D E R
?
5
ENTER
C H E C K
H O S E S
S T A R T
?
5
ENTER
W E I G H T =
X X . X L B
C O M P R E S S O R
O N
F I L L
C O M P L E T E
F I L L E D =
X X . X
L B
5
ENTER
*
H I G H
P R E S S U R E
S E E
M A N U A L
**
C Y L I N D E R
F U L L
G O
T O
C H A R G E
5
FILL CHARGE CYLINDER
Note:
For large capacity or multiple A/C Systems where recharge will NOT
be done between successive recoveries, it may be desirable to skip
this procedure.
1. Set up the AC880 as shown on Page 4 and then turn the Main Power Switch
ON.
Note:
The AC880 uses 22 lbs (10 Kg) of refrigerant when Filling the first
time. If the Refrigerant Cylinder (14) is emptied, the AC880 will
appear to stop filling (the Weight will stop rising) and will stay in this
condition until the RESET key is pressed.
2. Using the Keypad, press the “Up Arrow” key four times to display “WEIGHT=
XX.X LB” “FILL CYLINDER?
5” and press the ENTER key. The Display will
read “CHECK HOSES” “START?
5”.
3. Open the LIQUID Valve on the Refrigerant Cylinder (14) connected to the Fill
Port (13) with the Yellow Hose (15).
4. Press the ENTER key when ready to start filling the AC880.
The Display will read “WEIGHT=XX.X LB” “COMPRESSOR ON”. When the
level is approximately 20 lbs (9 kg), 75 percent of the full capacity, the AC880
will turn OFF, the Display will read “FILL COMPLETE” “FILLED= XX.X LB
5”
(the amount of refrigerant removed from the cylinder) and the Attention Light
will turn ON. Close the Liquid Valve on the Refrigerant Cylinder.
Note: Press the RESET button on the Keypad to stop the
Fill Cylinder procedure at any time.
5. Press the ENTER key to return to the Main Menu.
*
While filling the Charging Cylinder, this screen will display periodically
concurrent with the Attention Light turning ON. This is normal and nothing
to be concerned about. The screen should revert to normal after a few
seconds.
**
This screen will display when the Charging Cylinder fills to capacity,
approximately 24 lbs (11 Kg). If this occurs, the weight can be lowered
using the Charge procedure on Page 9 before the AC880 can be used to
recover more refrigerant. Press the ENTER key to return to the Main
Menu.
Note:
The AC880 Charging Cylinder can also be filled from the GAS or
VAPOR side of a cylinder by following the Recover/Recycle
procedure on Page 6.
Note:
The AC880 will use 1.1 lb (0.5 Kg) more refrigerant than the
displayed value the very first time it is used or after performing
a Calibration Procedure in order to prime the internal
components.
Note:
The Yellow Hose (15) can be removed from the Fill Port (13) and
connected to either the Blue or Red Hose connection port on the
rear of the AC880 to recover the refrigerant left in the Yellow
Hose (15) using the Recover/Recycle procedure on Page 6.
PROBLEMS ?
Refer to Page 18 should
problems be encountered using
the Fill Cylinder procedure.
Pressure differential between
the cylinder of new refrigerant
and the internal AC880 charge
cylinder greatly affect the
efficiency and speed of the Fill
Charge Cylinder procedure.