RECYCLE

1. Connect red and blue hoses to A/C and open valves.

2. Turn on power.

3. Press [

>] key one time.

4. Observe displays as shown to the left and enter data when

prompted.

5. Press [

#] key to move from one display to the next.

RECYCLE HOLD TIME

The AC2880 will recover refrigerant from the A/C until a stable
vacuum is sensed for at least two minutes. Times greater than
two minutes can be entered for the recycle hold time. The time
entered will be saved as the default.

HIGH PRESSURE - SEE MANUAL (Note A)

A condition of high pressure during the recycle process will
cause this message to be displayed. Turn the power off and
contact RTI Technical Service for assistance.

CYLINDER FULL - GO TO CHARGE (Note B)

If the charge cylinder fills to a maximum capacity of 17.5 lbs.
during the recycle process this message will be displayed. Press
the [

#] key to return to the main menu and go to the charge

procedure to transfer refrigerant to an external cylinder.