Trouble shooting guide and possible error messages – MAHLE RTI NTF-515 (Rev A) User Manual

Page 13

Advertising
background image

CLEAN AUTOMATIC DRAIN

Open the filter by turning the bowl one quarter turn counter-
clockwise.

Unscrew the nut (F).

Remove the drain unit (B-E) from the filter bowl (A).

Remove the O-ring (E).

Carefully pull the floating house (B) from the seat (D). Do not bend
the needle (C).

Clean the parts with soap and water. Make sure that the needle
bore is open and clean.

Assemble the parts in the opposite direction. Make sure that the
parts are dry before reassembly.

AUTOMATIC PRESSURE SWITCH SETTING

The automatic pressure switch is factory pre-set to shut off shop air consumption at 120 PSI. This
switch will then automatically reset when the N

2

Pressure inside the tank drops by approximately 25

PSI.

If your application requires an inlet pressure of 100 - 119 PSI, an adjustment to the automatic pressure
switch is possible. Please contact RTI Technical Support at 800-468-2321 x 1 for further details.

TROUBLE SHOOTING GUIDE AND POSSIBLE ERROR MESSAGES

Problem Possible

Cause Solution

1. Display does not light

Dead Battery

Recharge battery

2. Inflation process starts, but
does not complete

Low supply pressure or leaks
exist

Check supply pressure & confirm
leaks do not exist

3. Hose connectors will not seal
to the tire stems

Hose connections worn

Replace connectors

4. Hose connectors leak while
not connected to tires

Hose connections worn

Replace connectors

5. E4 on display

Over inflation due to blocked
hose

Remove blockage or replace hose

6. E5/E16 on display

Unit powered ON while
connected to tires

Remove hoses from tires and turn
power OFF/ON again

7. E6/E8/E9 on display

PCB or sensor error

Contact RTI Technologies

8. E10 on display

Low battery charge

Charge battery at least for 5 hours

9. E11/E12 on display

PCB fault

Contact RTI Technologies

13

Advertising