Empty used, Empty new, Close ball valve – MAHLE RTI ATX-2PS (Rev A) User Manual
Page 12
Page 11
EMPTY USED
1.
Connect red (positive) clamp on ATX power cable to red (positive) terminal on vehicle battery.
Connect the black (negative) clamp to a ground on vehicle frame. Vehicle engine is turned OFF.
The ATX-2 10 ft black and red hoses must be disconnected from the transmission. READY
light is off.
2.
Place end of 8 ft black hose (left side of ATX-2) hose in bulk used fluid container. Open ball
valve on the end of the hose.
3.
Press the EMPTY USED button on the keypad.
4.
Buzzer will sound and used transmission fluid will empty from the used tank inside the ATX-2
to the bulk container. Level can be viewed through the Level Indicator on the left side of the ATX-
2.
5.
Procedure will run until used tank is completely emptied or the STOP button is pressed. If
process is allowed to run until completion (30 seconds after used fluid tank is empty), the buzzer
will sound continuously and the PROCESS COMPLETE light will stay illuminated until the STOP
button is pressed.
6.
Close ball valve
on the black hose and remove it from the bulk used fluid container.
EMPTY NEW
1.
Connect red (positive) clamp on ATX power cable to red (positive) terminal on vehicle battery.
Connect the black (negative) clamp to a ground on vehicle frame. Vehicle engine is turned OFF.
The ATX-2 10 ft black and red hoses must be disconnected from the transmission. READY
light is off.
2.
Couple any fitting adapter to the end of the 10 ft red hose (right side of ATX-2). Place end of
hose in bulk storage container for later use.
3.
Press the EMPTY NEW button on the keypad.
4.
Buzzer will sound and new transmission fluid will empty from the new tank inside the ATX-2 to
the bulk storage container. Level can be viewed through the Level Indicator on the right side of
the ATX-2.
5.
Procedure will run until new tank is completely emptied or the STOP button is pressed. If
process is allowed to run until completion (30 seconds after new fluid tank is empty), the buzzer
will sound continuously and the PROCESS COMPLETE light will stay illuminated until the STOP
button is pressed.
6.
Disconnect fitting adapter from end of the 10 ft red hose.