IMPORTANT

Check transmission fluid level according to manufacturer’s

instructions before connecting the ATX-3

Transmission must be up to operating temperature

Adjust fluid level if required

Indicator

Slide

Hose

Dip Tube

Quick Coupler

Hose

Black

5

60-

80414-00

56

0-80

414-

00

Dipstick

Slide Indicator

Dip Tube Hose

Notch

DIPSTICK MODE

CONNECTING TO THE TRANSMISSION SYSTEM

1.

Remove transmission dipstick.

2.

Hold notched end of Dip Tube Hose even with the end of the dipstick as shown above.

3.

Position the slide Indicator so that is even with the cap end of the dipstick.

4.

Insert notched end of Dip Tube Hose into transmission so that the Slide Indicator is even with
the top of the dipstick port as shown above.

5.

Attach Quick Coupler to other end of Dip Tube Hose.

6.

Insert Quick Coupler into fitting on end of the black hose on the left side of the ATX-3.

Advertising