2 location - blended water installation, 2 location - cold water installation – Stuart Turner Monsoon Extra S1.4 bar Single User Manual
Page 6

- 6 -
Cont ...
2 LOCATION - BLENDED WATER INSTALLATION
2.26
Location: The pump must, for optimum performance, be sited as close as
possible to and never more than 4 metres from the HOT WATER cylinder. The
pump should always be sited BELOW the HOT WATER take-off from the cylinder.
2 LOCATION - COLD WATER INSTALLATION
2.27
The cold water supply: The supply must be AIR FREE and have a
DEDICATED CONNECTION to the tank which should be via a tank connector,
positioned at a slightly lower level (25 mm minimum) than the feed pipe to the hot
water
cylinder.
Do not connect to the mains.
Outlet head must be
below bottom of cold
water tank and able
to pass a minimum of
1 l/min of gravity flow
Fig. 2
Static inlet pressure
10
metres max
1
metre min
Fig. 3
Outlet head must be
below bottom of cold
water tank and able
to pass a minimum of
1 l/min of gravity flow
Static inlet pressure
10
metres max
1
metre min