Product description motor, Pump, Limits of application – Stuart Turner PH 35 TS User Manual

Page 3

Advertising
background image

- 3 -

Cont ...

PRODUCT DESCRIPTION
Motor:

Induction type, totally enclosed fan ventilated cooling*, continuously rated*, class ‘F’

insulation. Motors comply with IEC34-1. Single phase versions incorporate a permanent
capacitor and integral auto resetting thermal overload protection.

The standard range of motors are suitable for a supply of 230V, 1 phase, 50Hz.
Optional motors are available on certain models to suit various voltages and frequencies

(see technical specification for details).

*Variations of rating and enclosure details can be found in the technical specification

section.

Pump

All models are close coupled to motor.
PH 35 TS & PH 45 TS are of single stage, peripheral design, with vertical suction and

discharge ports.

PH 35 ES & PH 45 ES are of single stage, end suction, peripheral design.
Standard pump materials of construction of major wetted parts are as follows: -

* With footvalve fitted.

**Note: Max working pressure is the maximum pressure that can be applied to the

pump internal casing under any installation conditions.

Other seal material options are available on certain models.

LIMITS OF APPLICATION

Model

Body

Impeller

Shaft

Mechanical Seal

ALL

Brass

Brass

Stainless Steel

Nitril/Carbon
Ceramic/Stainless Steel

Model

Supply

Max.

Liquid

Temp.

o

C

Min.

Liquid

Temp.

o

C

Max.

Ambient

Air Temp

o

C

Max.

Suction

Lift (m)

Max. Head

(Pump

Closed

Valve) (m)

Max. Viscosity

**Max.

Working

Pressure

kPa (bar)

Max.

Inlet

Head

(m)

Max. No.

Starts/h

(Redwood No. 1

Scale)

Centistokes

PH 35 TS

230/1/50

80

4

40

4.6*

30.7

50

9.5

600 (6)

30

60

PH 45 TS

230/1/50

80

4

40

4.6*

41.6

50

9.5

600 (6)

19

60

PH 35 ES

230/1/50

80

4

40

4.6*

29.8

50

9.5

600 (6)

31

60

PH 45 ES

230/1/50

80

4

40

4.6*

42.0

50

9.5

600 (6)

19

60