Certain installations may require additional earthing arrangements such as equipotential
bonding. Reference should be made to the relevant regulations concerning this subject to
ensure compliance.
Wiring (Kennet range)
This product range must be permanently connected to fixed wiring and is provided with a
set of terminals which allow the connection of a flexible supply cord.
Select a cord and fuse size based on the motor full load current and the surrounding
conditions.
For information on cable fitting and connection, consult the wiring diagram and cable
gland and supply cord fitting instructions.
WARNING: This appliance must be earthed.
Wiring (Thame, Loddon and X201 range)
This product range is supplied with a factory fitted mains lead (supply cord). This must
be permanently connected to the fixed wiring.
The wiring in the mains lead are coloured in accordance with the following code:
Green and Yellow: Earth.
Blue: Neutral.
Brown: Live.
As the colours of the core in the new mains lead may not correspond with the coloured
markings identifying the terminals in your connection unit, proceed as follows:
Green and yellow coloured wire must be connected to the terminal marked with the letter
‘E’ or by the earth symbol
or coloured green or green and yellow.
Blue coloured wire must be connected to the terminal marked with the letter ‘N’ or
coloured black.
Brown coloured wire must be connected to the terminal marked with the letter ‘L’ or
coloured red.
WARNING: This appliance must be earthed.
Supply Cord Replacement (Thame, Loddon and X201 range)
If the supply cord is to be changed or is damaged, it must be replaced with a special cord
assembly available from Stuart Turner or one of their approved repairers.
On disassembly note the cord retention and routing system. Re-assemble to the same
pattern.
For information on cable connection consult the wiring diagram.
Fig. 9
Diagram of earth
continuity connection.