Stuart Turner Float Switch User Manual

Page 10

Advertising
background image

- 10 -

Cont ...

Earthing

WARNING: Earthing continuity between the supply cords to and from the
switch must be maintained.

The switch is provided with internal earthing terminals which are suitable for the

connection of the earthing conductors within the flexible supply cords.

Wiring

The switch is provided with a set of terminals which allow the connection of flexible

supply cords.

The supply cords should be of the PCP rubber insulated type (HO5RN-F) which is

suitable for a wet environment. Cable and fuse size must be appropriately selected. For
information on cable fitting consult the wiring diagrams and cable gland & supply cord
fitting instructions.

Ensure the electrical connections are securely made and that the micro switch is

connected in to the live line, not the neutral.

Cable Gland & Supply Cord Fitting Instructions (Single phase supply)

The cable gland assembly Fig. 15 (items 1 & 2) provides the necessary protection

against ingress of solid objects and moisture as well as providing cable retention.

Assembly instructions are as follows: -
1.

Ensure selected cable sheath

diameter is within the permitted range

(6.5 to 9.5 mm).

2.

Strip and prepare the cable sheath

and insulators as shown in Fig. 14.

3.

Disassemble cable gland as shown in

Fig. 15 and insert cable into position

ensuring ‘O’-ring (item 1) is placed

over the cable before the clamping

insert (item 2) is tightened.

4.

Consolidate the stranded conductor

ends by twisting.

5.

Insert the phase, neutral and earthing

conductors into the appropriate terminal

block connections (see wiring diagram)

and secure, ensuring all conductor strands

are

clamped.

8

E

N

L

70

70

8

8

100

Fig. 14

Fig. 15