b) Vertical suction models
This pump range are self venting and hence no priming plugs are fitted. Turn on
liquid supply and open outlet valve to allow pump to fill and vent.
4. Pre-Start
Check
Always ensure the pump is in a positive head position with flooded suction. A gravity
flow of approx. 0.6 l/min (RGFL/ESFL) or approx. 1 l/min (KFL, LFL & TFL) from the
highest outlet is required to operate the integral flow switch.
5. Starting
a) Switch on power and open terminal fitting. Pump should start and stop upon
demand.
b) Open and close all outlets in turn associated with the pump allowing liquid to flow
from each outlet until all air is purged. As each outlet is opened and closed the
pump will start and stop respectively.
c) Any tap or control valve within the system when opened and closed will now turn
the pump on/off. Check system for leaks, if clear the system is now operating
correctly.