Nexo Alpha System User Manual

Page 18

Advertising
background image

α

α

α

P 18

USER MANUAL

VERSION :1.01

DATE : 06/10/10

3.3.4. H

YGROMETRY AND

T

EMPERATURE

-

A

IR

A

BSORPTION

Under usual conditions, air absorption :

− increases when relative humidity decreases ;
− increases when temperature decreases.

Air absorption gives a linear attenuation, i.e. a constant value of loss of dB per meter : if 1 dB is lost from
10 to 20 meters, 2 dB will be lost from 20 to 40 meters, 4 dB from 40 to 80 meters and so on...

The tables below list these values for normalised frequencies, and various values of relative humidity and
temperature :

At 20°C :

[dB] loss / meter

Up to 1 kHz

2 kHz

4 kHz

8 kHz

16 kHz

RH

20% 0 0.02 0.06 0.20 0.66

RH

50% 0 0.01 0.03 0.08 0.27

RH

80% 0 0.00 0.02 0.05 0.17

Air absorption over a 50m distance ; RH=20%-50%-80%

At RH 50% :

[dB] loss / meter

Up to 1 kHz

2 kHz

4 kHz

8 kHz

16 kHz

10°C

0 0.01 0.04 0.13 0.43

20°C

0 0.01 0.03 0.08 0.27

30°C

0 0.01 0.02 0.06 0.19

Air absorption over a 50m distance ; t=10°C-20°C-30°C

20

100

1k

10k

20k

-40.00

-30.00

-20.00

-10.00

0.0

10.000

Frequency (Hz) / Attenuation (dB)

20

100

1k

10k

20k

FREQ(Hz)

-40.00

-30.00

-20.00

-10.00

0.0

10.000

LEVEL(dBV)

AUDIO PRECISION

vs

17 JUL 97 19:30:05

Advertising
This manual is related to the following products: