Usb commands and messages, Appendix – Boltek LD-350 User Manual

Page 18

Advertising
background image

U S B C O M M A N D S A N D M E S S A G E S

13

USB Commands and Messages

Commands

KA<cr> : keeps USB connection alive

VER<cr> : query firmware version

RESET<cr> : resets LD-350

FT<cr> : sends a forced trigger signal to LD-350

RAW<cr> : query raw data state
RAW <0,1><cr> : disable (0) or enable (1) raw data to be sent through USB

SQ<cr> : query squelch level

SQ<value 0-100><cr> : set squelch level

CAD<cr> : query close alarm distance

CAD<distance 0-250><cr> : set close alarm distance


CAT<cr> : query close alarm time

CAT<distance 0-250><cr> : set close alarm time

SAR<cr> : query severe alarm rate
SAR<0-999><cr> : set severe alarm rate

SAT<cr> : query severe alarm rate

SAT<0-999><cr> : set severe alarm rate

SAVE<cr> : saves current configuration to LD-350

READ<cr> : reads current LD-350 configuration

Appendix

A

Advertising