Environmental requirements, General specifications, Table 10 – Brocade VDX 6710-54 Hardware Reference Manual User Manual
Page 57: Table 11

Brocade VDX 6710-54 Hardware Reference Manual
39
53-1002390-08
Environmental requirements
A
Environmental requirements
lists the acceptable environmental ranges for both operating and nonoperating (such as
during transportation or storage) conditions.
General specifications
lists the general specifications for the Brocade VDX 6710-54.
TABLE 10
Environmental requirements
Condition
Acceptable during operation
Acceptable during non-operation
Ambient
Temperature
0º to 40ºC (32º to 104ºF)
-25º to 70ºC (-13º to 158ºF)
Humidity
10% to 85% RH non-condensing, at
40ºC (104ºF)
10% to 90% RH non-condensing, at 70ºC
(158ºF)
Altitude
0 to 3 km (9,842 feet) above sea level
0 to 12 km (39,370 feet) above sea level
Shock
20 G, 6 ms, half-sine wave
33 G, 11 ms, half-sine wave, 3/eg Axis
Vibration
0.5 G sine, 0.4 gms random, 5-500 Hz
2.0 G sine, 1.1 gms random, 5-500 Hz
Airflow
Maximum - 101.9 cmh (60 cfm)
Nominal - 74.8 cmh (44 cfm)
N/A
Heat
dissipation
444 BTU/hr
N/A
TABLE 11
General specifications
Specification
Description
System architecture
Nonblocking shared-memory switch
System processor
1.3 GHz PowerPC
Aggregate switch I/O bandwidth
108 Gbps
Port-to-port latency
Less than 600 nanoseconds on the same ASIC, 1.8 microseconds for
multi-ASIC