Historic statistics for delay measurement table – Brocade 6910 Ethernet Access Switch MIB Reference User Manual

Page 46

Advertising
background image

34

Brocade 6910 Ethernet Access Switch MIB Reference

53-1002652-02

3

Performance Monitoring of Delay Measurement Objects

Historic Statistics for Delay Measurement table

The mefSoamDmHistoricStatsTable contains statistics for historic intervals in a Delay
Measurement session.

Name, Identifier, and Syntax

Access

Description

mefSoamDmHistoricStatsTable
1.3.6.1.4.1.15007.1.3.1.3.5
Syntax: SEQUENCE OF
MefSoamDmHistoricStatsEntry

N/A

This table contains the results for historic Measurement
Intervals in a SOAM Delay Measurement session.
Rows of this table are created automatically by the SNMP
Agent when the Delay Measurement session is running and
a measurement interval is completed.
Supports 32 completed measurement intervals. If a new
measurement interval completes and must be added to the
table, the oldest completed measurement interval may be
deleted (row deletion).
Unless otherwise indicated, the objects in this table are
ignored if mefSoamDmType is 1DmTx.
Except for mefSoamDmHistoricStatsIndex and
mefSoamDmHistoricStatsSuspect, each object in this table
applies only if the corresponding bit is set in
mefSoamDmCounterEnable.
The rows and objects in this table must be persistent upon
reboot or restart of a device.

mefSoamDmHistoricStatsEntry
1.3.6.1.4.1.15007.1.3.1.3.5.1
Syntax:
MefSoamDmHistoricStatsEntry

N/A

The conceptual row of mefSoamDmHistoricStatsTable.

mefSoamDmHistoricStatsIndex
1.3.6.1.4.1.15007.1.3.1.3.5.1.1
Syntax: Unsigned32

N/A

The index for the measurement interval within this PM
session.
Measurement Interval indexes are assigned sequentially by
the SNMP Agent. The first Measurement Interval that occurs
after the session is started is assigned index 1.
This object applies regardless of the value of
mefSoamDmType.
Referential integrity is required, i.e., the index needs to be
persistent upon a reboot or restart of a device. The index can
never be reused for other completed measurement intervals
on the same MEP for a particular DM session. The index
value should keep increasing up to the time that it wraps
around. This is to facilitate access control based on OID.

mefSoamDmHistoricStatsEndTime
1.3.6.1.4.1.15007.1.3.1.3.5.1.2
Syntax: DateAndTime

Read-only

The time that the measurement interval ended.
This object applies regardless of the value of
mefSoamDmType.

mefSoamDmHistoricStatsElapsedT
ime
1.3.6.1.4.1.15007.1.3.1.3.5.1.3
Syntax: TimeInterval

Read-only

The length of time that the measurement interval ran for, in
0.01 seconds.
This object applies regardless of the value of
mefSoamDmType.

mefSoamDmHistoricStatsSuspect
1.3.6.1.4.1.15007.1.3.1.3.5.1.4
Syntax: TruthValue

Read-only

Whether the measurement interval has been marked as
suspect.