Identifying sim ports – Brocade Flow Vision Administrators Guide (Supporting Fabric OS v7.3.0) User Manual

Page 72

Advertising
background image

‐

EX_Port

‐

F_Port trunked

‐

Fastwrite port

‐

FCoE port

‐

ICL port

‐

L_Port

‐

M_Port (Mirror Port)

‐

VE port

• If a port is configured with CSCTL_mode enabled, you can configure it as a SIM port.
• If a port has an Ingress Rate Limit set, you can configure it as a SIM port.
• If a port is configured as a SIM port:

‐

You cannot enable QoS.

‐

You cannot enable CSCTL_mode.

‐

You can set an Ingress Rate Limit.

• The following features of a SIM port are persistent across a reboot:

‐

Each SIM port is assigned a PID and is displayed in a switchShow command.

‐

Each SIM port’s Port Worldwide Name by default is the switch Port Worldwide Name
(PWWN), unless a user-defined Virtual Port Worldwide Name is assigned to it.

‐

Each SIM port registers itself into the Name Server database.

Identifying SIM ports

In order to distinguish SIM ports from other devices, the Name Server commands show “Port
Properties: SIM Port”, as called out in the following example:

switch:admin> nscamshow

nscam show for remote switches:

Switch entry for 105

state rev owner cap_available

known v730 0xfffc6e 1

Device list: count 12

Type Pid COS PortName NodeName

N 691000; 3; 10:00:00:00:00:0f:00:00;10:00:00:00:00:00:0f:00;

Fabric Port Name: 20:10:00:05:1e:57:dc:b3

Permanent Port Name: 10:00:00:00:00:0f:00:00

Port Index: 16

Share Area: No

Device Shared in Other AD: No

Redirect: No

Partial: No <— Port Properties is not shown for non-SIM ports

N 691400; 2,3; 20:14:00:05:1e:57:dc:b3;20:14:00:05:1e:57:dc:b3;

Fabric Port Name: 20:14:00:05:1e:57:dc:b3

Permanent Port Name: 20:14:00:05:1e:57:dc:b3

Port Index: 20

Share Area: No

Device Shared in Other AD: No

Redirect: No

Partial: No

Port Properties: SIM Port <— Port Properties shows "SIM Port"

(output truncated)

switch:admin> nsshow

Type Pid COS PortName NodeName TTL(sec)

N 691000; 3; 10:00:00:00:00:0f:00:00;10:00:00:00:00:00:0f:00; na

Fabric Port Name: 20:10:00:05:1e:57:dc:b3

Permanent Port Name: 10:00:00:00:00:0f:00:00

Port Index: 16

Share Area: No

Device Shared in Other AD: No

Redirect: No

Partial: No

LSAN: No <— Port Properties is not shown for non-SIM ports

N 691400; 2,3; 20:14:00:05:1e:57:dc:b3;20:14:00:05:1e:57:dc:b3; na

Fabric Port Name: 20:14:00:05:1e:57:dc:b3

Identifying SIM ports

72

Flow Vision Administrators Guide

53-1003168-01

Advertising