Messages that may indicate WWN card failure (Continued)
TABLE 9
Type of message
Sample error message
WWN unit is being faulted.
0x24c (fabos): Switch: switchname, Critical EM-
WWN_UNKNOWN, 1, Unknown WWN #2 is being
faultedor<timestamp>, [EM-1003], 40, SLOT 7 | FFDC |
CHASSIS, CRITICAL, Brocade_DCX, WWN 2 has unknown
hardware identifier: FRU faultedor<timestamp>,
[EM-1034], <sequence-number>,, ERROR, <system-name>,
WWN # set to faulty, rc=<return code>
WWN unit is not present or is not
accessible.
0x24c (fabos): Switch: switchname, Error EM-
WWN_ABSENT, 2, WWN #1 not presentor<timestamp>,
[EM-1036], <sequence-number>,, WARNING, <system-
name>, <FRU Id> is not accessible.
Writing to the FRU history log
(hilSetFruHistory) has failed.
0x24c (fabos): Switch: switchname, Error EM-HIL_FAIL,
2, HIL Error: hilSetFruHistory failed, rc=-3 for SLOT
3
WWN unit insertion was detected.
<timestamp>, [EM-1049], <sequence-number>,, INFO,
<system-name>, FRU WWN # insertion detected.
WWN unit removal was detected.
<timestamp>, [EM-1050], <sequence-number>,, INFO,
<system-name>, FRU WWN # removal detected.
The following figure displays the WWN bezel (logo plate). The WWN cards are under the bezel.
FIGURE 18 WWN bezel (logo plate) for DCX-4S and DCX 8510-4
Monitoring System Components
60
Brocade DCX 8510-4 Backbone Hardware Reference Manual
53-1002177-07