Changing the filter cartridge – Davey Aquashield Centurion 50W & 70W User Manual

Page 8

Advertising
background image

8

Changing the Filter Cartridge

1. Turn off the water flow to the cartridges at the valve, tank or tap.
2. Release the pressure by opening a tap downstream, or use the pressure relief

valve that is available in the lid of the filter housings.

3. Unscrew the bottom housing from the lid* and remove the used cartridge and

discard or wash. The inside of the filter housing and the lid should be checked for
cleanliness - they will usually need to be cleaned or sanitised - use hot water and
dishwashing liquid, thoroughly scrub all surfaces and then rinse.

4. Check that the o-ring is in position in the top of the housing base, lubricate with

a coating of white petroleum jelly (Vaseline), place the o-ring into the groove and
with two fingers wipe the o-ring down into the groove. Do not wipe the o-ring clean
of lubricant after it has been properly seated in the groove because the lubricant
prevents “crawling” of the o-ring during the tightening of the lid and thus prevents
water leaks.

5. Screw the housing onto the lid and hand tighten. Open the tap downstream of the

filter and then open the inlet valve.

*The cartridge spanner supplied with the unit may help if the housing is tight.

CAUTION: The housing must be protected against freezing. Failure to do so
may result in cracking of the housing and water leakage.

WARNING: CAREFULLY AND GENTLY TIGHTEN WITH HOUSING SPANNER
as the bowl should only be tightened enough to avoid water leaking during
operation.

WARNING: If the water system is not going to be used for extended periods,
the cartridge should be removed from the housing and replaced with a new or
cleaned cartridge when the system is used again.

IMPORTANT: When opening the filter housing to install or change the
cartridge (element) it is common for the o-ring seal to lift out of the groove
and, at times, it may even stick to the cap.

CAUTION WHEN INSTALLING
1. This is a plastic product with a female thread. If you cross-thread a male

fitting, and/or you over pack with sealing tape, you could do permanent
damage.

2. If you use a tapered thread male fitting do not over tighten.
3. No warranty claims will be considered for damage due to incorrect installation.

Your new Aquashield Centurion system incorporates a Steriflo® includes a lamp
failure system design feature that enables you to be warned of a lamp failure by :-
1. A lamp failure LED.
2. An audible alarm.
In addition when the alarm “beeps” on and off, the lamp is due to be changed so that
effective treatment is maintained.