Power Connection

Connect lead to power supply designated on control box label. Earth stainless

steel chambers using bolt provided on the chamber.

WARNING: When servicing or attending your Steriflo

®

, always

ensure power is switched off and lead unplugged. Electrical

connections should be serviced only by qualified persons. If any

of the electrical supply leads of this system are damaged, they

must only be replaced by a qualified service person.

The Steriflo

®

control box has a red LED alarm indicator light

mounted on its front panel, adjacent to the amber “power on” LED.

This light will be illuminated whenever the Steriflo

®

control box

senses no lamp current. There is also an audible alarm in the

event of lamp failure. The LED and/or alarm will only work when

unit is connected to the correct electrical supply.

Install the power supply enclosure above the treatment chamber

so that in the event of a leak, water cannot drip down the lamp

lead into the enclosure.

CAUTION: The supply cord is necessary for lamp changing. The

three pin supply plug must remain accessible after installation. If

installed to fixed wiring without the plug a two pole switch must be

fitted and its ON and OFF positions shall be marked.
The lead containing an outlet plug is for easy connection to a

water pump. Ensure flow rate of the pump does not exceed rated

flow of the UV system or maximum rated current draw of 5.7A.

Should the unit alarm, power to the pump will be interrupted

ensuring safe water is always supplied. Manual overriding of this

feature is available by briefly pressing the reset button once for

emergency water supply.

If pump outlet is not required retain plastic guard supplied on

pump outlet.