Eco-spa, Installation instructions, Davey – Davey EcoSpa Salt Water Spa Sanitisation System User Manual

Page 4: Repair or replacement guarantee

Advertising
background image

4

9

ECO-SPA

TM

INSTALLATION INSTRUCTIONS

(Refer to diagram next page)

1. Please ensure the EcoSpa™ Control Unit is mounted a minimum of 3 metres

away from the spa water and 1.5 metres above ground level. For a portable

spa, the EcoSpa™ unit can be fitted on the inside of the spa surround, please

ensure easy access.

2. Select mounting point and mark 2 holes 18mm apart. (If the unit is to be

mounted to a brick or concrete wall use a masonry drill bit. Some walls such

as limestone or cement render can damage aluminium, if in doubt seal the wall

before mounting the control unit). Drill the 2 holes and fix suitable screws to

each hole. Recommended screws are 8 gauge.

3. Hang unit via slots in the top rear section of EcoSpa™ unit. NB: The additional

mounting hole at the base of the EcoSpa™ can be used to help secure the unit.

4. Plug power plug from control unit into a suitable weatherproof power outlet.

Ensure appropriate RCD safety device is fitted to mains power. Do not turn

power on until installation is complete. When used with controller, plug into

ozone position and set dip switches H & I to 1.

5. Install Manifold for ORP Sensor Probe and Pressure Switch into spa return

line after the pump.

6. Plumb Electrolytic Cell into spa return line injection housing. Plug Cell

connector into the appropriate receptacle in the bottom of the unit. The Cell can

be installed vertically or horizontally. NOTE: ORP Sensor and pressure switch

MUST be installed prior to the Cell and at least 200mm (8”) from the Cell inlet,

preferably further away.

IMPORTANT NOTICE:

For installations where manifold is not used, the pressure

switch must be installed at suitable point on spa return. If return does not

have enough pressure fit the pressure switch between pump return and filter.

The pressure switch should be tapped into a point where the pipe enters a fit-

ting to allow a good thread length. Tap size is 1/8” NPT. Take care not to damage

threaded end and use thread tape for a good seal.

Fit ORP Sensor Probe at least 200mm (8”) before Cell. To fit ORP Sensor Probe

drill hole and tap with a 1/4” BSPF tap. This must be done carefully to ensure a

good threaded fit. Screw the ORP Sensor Probe into the pipework. Note that it is

best to fit the ORP Sensor Probe into a fitting (elbow, coupling, etc) to ensure good

thread length.

7. Connect the pressure switch to the EcoSpa™ Control Unit via the cable

terminated in two insulated pade connectors. Note that the pressure switch is

not waterproof and should not be exposed to the weather.

8. Connect ORP Sensor Probe to socket under EcoSpa™ Control Unit.

* Installation and operating instructions are included with the product when purchased new.

They may also be found on our website.

AUSTRALIA
Davey Support Centre

6 Lakeview Drive,

Scoresby, Australia 3179

Ph:

1300 367 866

Fax:

1300 369 119

Website: davey.com.au

Davey Water Products Pty Ltd
Member of the GUD Group
ABN 18 066 327 517

NEW ZEALAND
Customer Service Centre

7 Rockridge Avenue,

Penrose, Auckland 1061

Ph:

0800 654 333

Fax:

09 527 7654

Website: daveynz.co.nz

® Davey is a registered trademark of Davey Water Products Pty Ltd.
© Davey Water Products Pty Ltd 2012.

Davey

®

Repair or Replacement Guarantee

In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction
within warranty periods beginning from the date of original purchase due to faulty materials or
manufacture, Davey will at our option repair or replace it for you free of charge, subject to the
conditions below.

Davey Guarantee Period

Control Box - Two Years

Electrolytic Cell - Three Years ORP Probe - Three Years

Should you experience any difficulties with your Davey product, we suggest in the first instance
that you contact the Davey Dealer from which you purchased the Davey product. Alternatively
you can phone our Customer Service line on 1300 367 866 in Australia, or 0800 654 333 in New
Zealand, or send a written letter to Davey at the address listed below. On receipt of your claim,
Davey will seek to resolve your difficulties or, if the product is faulty or defective, advise you on how
to have your Davey product repaired, obtain a replacement or a refund.

Your Davey Guarantee naturally does not cover normal wear or tear, replacement of product
consumables (i.e. mechanical seals, bearings or capacitors), loss or damage resulting from
misuse or negligent handling, improper use for which the product was not designed or advertised,
failure to properly follow the provided installation and operating instructions, failure to carry out
maintenance, corrosive or abrasive water or other liquid, lightning or high voltage spikes, or
unauthorized persons attempting repairs. Where applicable, your Davey product must only be
connected to the voltage shown on the nameplate.

Your Davey Guarantee does not cover freight or any other costs incurred in making a claim.
Please retain your receipt as proof of purchase; you

MUST provide evidence of the date of original

purchase when claiming under the Davey Guarantee.

Davey shall not be liable for any loss of profits or any consequential, indirect or special loss,
damage or injury of any kind whatsoever arising directly or indirectly from Davey products. This
limitation does not apply to any liability of Davey for failure to comply with a consumer guarantee
applicable to your Davey product under the Australian or New Zealand legislation and does not
affect any rights or remedies that may be available to you under the Australian or New Zealand
Consumer Legislation.

In Australia, you are entitled to a replacement or refund for a major failure and for compensation for
any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired
or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major
failure.

Should your Davey product require repair or service after the guarantee period; contact your
nearest Davey Dealer or phone the Davey Support Centre on the number listed below.

For a complete list of Davey Dealers visit our website (davey.com.au) or call:

Advertising