The wall ring should be positioned against the unfinished pool wall, with the marking “

TOP

in the 12 o’clock position. The finished wall must lay level with the front face of the
wall ring to a diameter of 25cm (10”).

The mounting skirt ring is then screwed to the wall ring with the front lug at the 6 o’clock
position.

Feed the cable through the conduit, retaining sufficient free cable behind the light assembly
to facilitate future service above water level. Normally 1.2 metres (4ft) is sufficient. This
extra cable is secured by the retaining brackets at the rear of the light.

On concrete pool installations it is recommended that once sufficient lead has been allowed
for servicing, the installer apply silicone into the conduit around the lead, to prevent, where
possible, the water from tracking along the conduit.

The light assembly is then located on the bottom lug of the mounting skirt ring and clipped
into the corresponding slot at the top of the mounting skirt and secured by a stainless steel
screw.

Diagram of Below Ground Concrete Pool Installation