Congratulations

on choosing the latest Spa Power control system. This

controller makes use of the latest technology, including innovative optical and
digital sensor designs.The greater variety of optional accessories, user-friendly
touchpad and reliable components provide you with the most sophisticated
controller in its class.

Installation & Safety Notes

1. When installing this spa pool control system, refer to the appropriate local wiring rules. In particular

refer to AS/NZS 3000:2007 (AS /NZ) and EN60364 (EU). Follow the wiring rules to ensure
equipment is located in the correct zones for water protection. This spa pool control system must
be protected from water in an IPX5 enclosure or cabinet.

2. It is recommended that the steel reinforcing in any concrete base on which the pool is sitting be

equipotential bonded to the earth conductor in the supply to the spa. This is to protect against the
possibility of low voltage shocks caused by differential earth voltages. Refer to the appropriate
local wiring rules, e.g. AS/NZS3000:2007 Sections 5.6 & 6.3 or EN 60364.

3. Parts containing live parts must be inaccessible to a person in the spa, except parts supplied with

safety extra-low voltage not exceeding 12V (e.g. touch pads and LED lights).

4. Parts incorporating electrical components, except remote control devices, must be

located or fixed so that they cannot fall into the spa. Portable appliances must not be located
above the spa during use.

5. The appliance must be supplied through a residual current device (RCD) having a rated residual

current not exceeding 30mA.

6. If a supply plug is not fitted or if the system is installed in Europe then the system must be

permanently connected to fixed wiring. Means for all pole disconnection must be provided in the
fixed wiring in accordance with the wiring rules.

7. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or

similarly qualified persons in order to avoid a hazard.

8. This appliance is not intended for use by persons (including children) with reduced physical,

sensory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.

9. In order to avoid the possibility of hyperthermia (heat stress) occurring, it is recommended that the

average temperature of spa pool water should not exceed 40°C.

10. For proper operation the spa pool must be fitted with an effective thermally insulating cover when

not in use.

7 Sleep Timer (Optional Timeclock)

If the optional time clock has been fitted, sleep mode is used to disable
automatic temperature maintenance and filtration in order to silence
the spa pool during your hours of sleep.The sleep time setting is done
using the digital time clock on the front of the control box (See below
for setting instructions). If the spa is in use it will not enter sleep mode
until 30 minutes after the last manual button push, even if the clock is
calling for sleep mode. The spa can still be used manually within sleep
mode times as normal. On wake up from sleep the system will run the
blower for 15 seconds to purge the blower plumbing. This prevents any
stagnant water from collecting in the pipes if the pool is not used for an
extended period.

7.1 To Set Current Time and Day

1. Press the RESET button before use. NOTE:This is optional. It will clear the current time and

program settings.

2. Hold down the CLOCK button and press the DAY button until the correct day is selected.Release

both buttons.

3. Hold down the CLOCK button and press the HOUR button until the correct hour is set.Release both

buttons.

4. Hold down the CLOCK button and press the MIN button until the correct minute is set.Release both

buttons.

5. After setting the weekday and time,the seconds will reset automatically and the clock will begin

keeping time.

7.2 To Set Programs

1. Press the TIMER button. “1ON” will appear at the left side of the display. This is the start time of the

first programmed sleep block (the time you want the spa to enter the sleep mode).

2. Press the DAY button to select the days on which this sleep program will operate.There are15

settings to choose from.

3. Press the HOUR button to set the hour of the desired time to enter sleep mode.
4. Press the MIN button to set the minutes of the desired time to enter sleep mode.
5. Now the start time has been set, press the TIMER button again. “1OFF” will appear on the display.

This is the end time of the first programmed sleep block (the time you want the spa to resume
normal operation).

6. Repeat the same procedure (2 to 4 above) until the “1OFF” time is set. (Becareful to set the same

days as used in the “1ON” time).

7. Your timer gives you upto 8 different programmable periods.You can use all 8 settings,or as few as

you like.

8. To Review your set programs press the TIMER button and keep pressing it to advancet hrough

each setting.

IMPORTANT NOTE: The “MANUAL” button on the clock can be used to override the programmed
sleep settings. It is very important to ensure that the clock is set to “AUTO” so that the programmed
times can operate. If the clock is manually set to ON then the pool will stay in sleep mode and THE
WATER WILLGO COLD. If it is left in “OFF” then the pool will not enter the sleep mode. The clock
does not return to “AUTO” byitself.

NOTE: If the “MANUAL” button on the clock is used the spa will not return to the programmed settings
until thenextprogrammedtimeafterbeingreturnedtoAuto.