Hired-Hand Circulation and Stir Fans: 52 Orifice Fan HSP Conversion Kit User Manual
Page 2

HIRED-HAND MFG., INC.
• 1733 Co Rd 68 • Bremen, Alabama 35033 • Phone 256-287-1000 • Fax 265-287-2000
Manual Part Number 4802-5150 Rev 3-05
Page 2
13. Attach the motor removed in Step 7 above to the
Top Fan Brace. Note there are two mounting
positions for the motor. Use the UPPER motor
mounting position. See Detail C.
14. Attach the belt tensioner removed in Step 6
above to the tensioner bracket. Reuse the
existing hardware. See Detail D.
15. Align all pulleys with straight edge. See
Detail E.
16. Install fan belt removed in Step 3 above onto
motor pulley, tension pulley, and prop pulley.
17. Attach the power cable to the motor. Ensure
that the rotating fan blade will not come in contact
with the power cable or the fan frame.
18. Test the fan for proper operation.
19. Installation complete.
DETAIL B
DETAIL D
Install
Tensioner
in mount
Detail C
Lock Nut
Bolt 5/16-18 x ¾”
Belt
NOTE: In this view the Idler Pulley is directly
under the Motor pulley
.
Detail E
Motor pulley
Straight edge
Prop pulley
DANGER!
Do Not Install Fan Within Range Of Human Or Animal Contact!