Super Saver XL Heater Maywick

HEATER DIMENSIONS

WEIGHT

130 lb. (60 kg)

HEIGHT

30 in. (76.2 cm)

WIDTH

24-1/2 in. (62.2 cm)

DEPTH

19-1/4 in. (48.9 cm)

Table Of Contents

1.

Specifications And Requirements..................4

2.

Warnings And Cautions .................................6

3.

Maintenance And Warranty ...........................7

4.

Installation......................................................8

5.

User Instructions ............................................9

6.

Outside Mount (Optional).............................10

7.

Component And Wiring Diagram .................11

8.

Ladder Type Schematic Diagram ................12

9.

Servicing Instructions...................................13

10.

Pipe Sizing Guidelines.................................18

11.

Parts & Assemblies......................................20















1.

Specifications And Requirements



















MINIMUM CLEARANCES

Heater must be located a minimum of 12 inches (305 mm) from ceiling, a minimum of 12 inches (305 mm) from wall,

a minimum of 20 inches (305 mm) from ground, and positioned so that livestock are unable to come in contact with

heater or within 10 feet (3 meters) of hot air discharge. (See Figure 1 - Installation Instructions).

Be Sure To Check

Delivery

!

Locate packing slip and make sure
all of the listed parts are enclosed.
If not, call your Hired-Hand
Distributor immediately.

Adjustable Wrench

Gas Leak Testing Solution

Pipe Glue

1/4

″ (7 mm)

Nut Driver

Install screw hooks with hammer or drill.

Model No.

Maximum Input

Ventilation

(air required to support combustion)

SS-225-XL

225,000 BTUH (65.9 kW)

1000 CFM (1699 m

3

/hr)

LP/Propane Gas

Maximum 14 in. W.C. (34.8 mbar) and minimum 12.5 in. W.C. (31.1 mbar) inlet gas supply
pressure acceptable at gas regulator connection. Burner manifold pressure 11 in. W. C.
(27.4 mbar) at maximum input. Gas pressure should be checked by a certified gas
technician while heater is in operation.

Natural Gas

Maximum 14 in. W.C. (34.8 mbar) and minimum 5 in. W.C. (12.5 mbar) inlet gas supply
pressure acceptable at gas regulator connection. Burner manifold pressure of 3.5 in. W. C.
(8.7 mbar) at maximum input. Gas pressure should be checked by a certified gas
technician while heater is in operation.

Refer to heater ratings plate for unit voltage, amperage, and frequency ratings.