Installation, Physical dimensions, Rated output & additional output capacity – Lincoln Electric IM609 SQUARE WAVE TIG 275 User Manual

Page 8

Advertising
background image

A-1

INSTALLATION

SQUARE WAVE TIG 275

A-1

TECHNICAL SPECIFICATIONS - Square Wave TIG 275 (K1617-1, and -2)

For AC/DC Stick, DC TIG and Balanced AC TIG

Welding at 275A 40% Duty Cycle

w/o Optional K1620-1 Power Factor Capacitors

Based on the 1996 U.S. National Electrical Code

For Unbalanced AC TIG Welding above 180A,

255A 40% Duty Cycle, Maximum Penetration

w/o Optional K1620-1 Power Factor Capacitors

Based on the 1996 U.S. National Electrical Code

INPUT - SINGLE PHASE ONLY

RECOMMENDED INPUT WIRE AND FUSE SIZES

Input

Voltage /

phase/

Frequency

208/1/60

230/1/60

460/1/60

575/1/60

Input

Amperes

111

100

50

40

Type 75°C

Copper Ground

Wire in

Conduit AWG

(IEC) Sizes

6 (13.3 mm2)

6 (13.3 mm2)

10 (5.3 mm2)

10 (5.3 mm2)

Fuse

(Super Lag)

or Breaker

Size

(1)

125

125

60

50

Type 75°C

Copper Wire in

Conduit AWG

(IEC) Sizes

40°C (104°F) Ambient

4 (21.2 mm2)

4 (21.2 mm2)

8 (8.4 mm2)

10 (5.3 mm2)

Type 75°C

Copper Ground

Wire in

Conduit AWG

(IEC) Sizes

6 (13.3 mm2)

6 (13.3 mm2)

8 (8.4 mm2)

10 (5.3 mm2)

Type 75°C

Copper Wire in

Conduit AWG

(IEC) Sizes

40°C (104°F) Ambient

3 (25.0 mm2)

3 (25.0 mm2)

8 (8.4 mm2)

8 (8.4 mm2)

Input

Amperes

130

120

61

49

Height

Width

Depth

Weight

Power

24.06 in.

19.15 in.

28.00 in.

Approx. 330 lbs.

Source

611 mm

486 mm

711 mm

150 kg.

Lift Hook add 3.57” (91 mm)

Power Source

33.40 in.

27.65 in.

40.65 in.

Approx. 375 lbs.

on

848 mm

702 mm

1033 mm

170 kg.

Undercarriage

PHYSICAL DIMENSIONS

Fuse

(Super Lag)

or Breaker

Size

(1)

150

150

70

60

(1)

Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers which have a delay in tripping action that decreases as the magnitude of cur-
rent increases.

Code

Number

10523
10525
10605

Input Current at

Input Current at

Input Current at

Idle

Idle Power

40% Duty Cycle

60% Duty Cycle

100% Duty Cycle

Current

Power

DC STICK,

DC STICK,

DC STICK,

DC TIG,

UNBALANCED AC TIG DC TIG,

UNBALANCED AC TIG DC TIG,

UNBALANCED AC TIG

BALANCED AC TIG

BALANCED AC TIG

BALANCED AC TIG

95/86/43

130/120/61

76/69/34

106/97/50

57/52/26

82/75/38

5/4/2 900 WMax.

43/35

61/49

34/28

50/41

26/21

38/31

2/1.5 900 WMax.

95/86/43

130/120/61

76/69/34

106/97/50

57/52/26

82/75/38

5/4/2 900 WMax.

Standard

Voltage

208/230/460/1/60 (K1617-1)

460/575/1/60 (K1617-2)

208/230/460/1/60 (K1617-1)

RATED OUTPUT & ADDITIONAL OUTPUT CAPACITY

Duty Cycle

Amps

Volts at Rated Amperes

Current Range

Auxiliary Power

40% Duty Cycle AC/DC Stick

275 A

31.0 V

5-315 Amps

115 Volts AC, 10 Amps

NEMA Class II (40) AC/DC TIG

255 A

16.1 V

Grounded NEMA-5-15R

Receptacle and

60% Duty Cycle AC/DC Stick

225 A

29.0 V

MAX O.C.V.

10 Amp Circuit Breaker

AC/DC TIG

200 A

15.4 V

AC & DC 80V

100% Duty Cycle AC/DC Stick

175 A

27.0 V

Normal O.C.V.

AC/DC TIG

150 A

14.8 V

72 V (AC) 59 V (DC)