INSTALLATION

DC-400

A-8

To change stick polarity, reverse the leads at the (+)
and (-) terminals on the right side of the Multiprocess
Switch.

NOTE: When a DC-400 equipped with Multiprocess

Switch is mounted on an undercarriage, the
undercarriage handle in the resting position
can hit the case of the Multiprocess Switch.
This does no harm, but if the user desires, a
1/4

or 3/8

bolt and nut may be placed in the

hole in the undercarriage tow bar to limit the
travel of the undercarriage handle.

STICK, TIG OR AIR/CARBON ARC *

a) Turn off all power.

b) Disconnect all wire feed unit control, electrode, and

work leads.

c) Place MODE SWITCH in the

CONSTANT CUR-

RENT (STICK/TIG)

for air carbon arc.

d) For stick, TIG or air carbon arc, place OUTPUT

TERMINALS switch into the

ON

position. With

the DC-400 connected for stick, TIG or air carbon
arc welding, the output terminals will be energized
at all times.

*NOTE: If stick welding, TIG welding or air carbon arc

cutting is to be done on the DC-400 along
with semi-automatic/automatic welding, then
a K804-1 Multiprocess Switch is required. If
the Multiprocess Switch is not used, then all
control, electrode, and work leads to wire
feed equipment must be disconnected from
the DC-400 before connecting the DC-400 for
stick or air carbon arc cutting.

MULTIPROCESS SWITCH

WORK

ELECTRODE

To semi-

auto or

auto

equipment

To stick
electrode
holder or
air carbon
arc torch

User supplied
4/0 (107 mm )
jumper

2

+