CONNECTION OF AN LN-23P WIRE
FEEDER TO THE COMMANDER 500

a. Shut the welder off.

b. Connect the LN-23P per instructions on the appro-

priate connection diagram in the DIAGRAMS sec-
tion. (NOTE): When connecting an LN-23P to the
Commander 500, a K350-1 adapter kit must be
used.

c. Set the

“

VOLTMETER

”

switch to

“

-

”

.

d. Set the

“

SELECTOR

”

switch to

“

WIRE WELDING

”

position.

e. Set the

“

WELDING TERMINALS

”

switch to

“

WELD-

ING TERMINALS ALWAYS ON

”

.

f. Set the ARC CONTROL to desired crispness. SOFT

for MIG - crisp for Innershield.

g. Set the

“

LOCAL/ REMOTE

”

switch to the desired

setting depending upon where the power sources
output is being controlled from.

h. Set the

“

IDLE

”

switch to the

“

HIGH

”

position. If you

are using an LN-23P with the K350-1 adapter kit,
the electrode is not energized until the gun trigger is
closed.

CONNECTION OF AN NA-3 AUTOMATIC
WELDING SYSTEM TO THE COMMANDER
500

For connection diagrams and instructions for connect-
ing an NA-3 Welding System to the Commander 500,
refer to the NA-3 Welding System instruction manual.
The connection diagram for the LN-8 can be used for
connecting the NA-3.

CONNECTION OF AN LN-742 TO THE
COMMANDER 500

(Requires optional K1597-1,

42 VAC Transformer Kit).

a. Shut the welder off.

b. Connect the LN-742 per instructions on the appro-

priate connection diagram in the DIAGRAMS sec-
tion.

c. Set the

“

LOCAL/ REMOTE

”

switch to REMOTE.

d. Set the

“

WIRE FEEDER VOLTMETER

”

switch to

either

“

+

”

or

“

-

”

as required by the electrode being

used.

e. Set the

“

SELECTOR

”

switch to the

“

WIRE WELD-

ING-CV

”

position.

f. Adjust the

“

ARC CONTROL

”

knob to desired

Crispness.

SOFT for MIG and CRISP for

Innershield.

g. Set the

“

WELDING TERMINALS

”

switch to the

“

WELDING TERMINALS

”

REMOTELY CON-

TROLLED

”

position.

h. Set the

“

IDLE

”

switch to the

“

AUTO

”

position. When

not welding, the Commander 500 engine will be at
the low idle speed.