A-1

CV-300

A-1

INSTALLATION

TECHNICAL SPECIFICATIONS – IDEALARC CV-300

Code

Number

10180

10181

Volts at Rated Amperes

32

36
32

Auxiliary Power

42 Volts AC, 10 Amps
115 Volts AC, 5 Amps

( Both Circuit Breaker Protected)

Idle Current - Amps

11/10/5

Input Current at

Rated Output

100% Duty Cycle 66/60/30

60% Duty Cycle 67/61/31

100% Duty Cycle 60/30/24

60% Duty Cycle 61/31/25

Amps

300

400
300

Normal Open Circuit Voltage

10-43

MAX OCV: 50

Input kVA

60% Load - 24.1

100% Load - 23.8

Power Factor at 100% Load

.61

Standard

Voltage

208/230/460/3/60

230/460/575/3/60

Duty Cycle

100% Duty Cycle

NEMA Class I (100)

60% Duty Cycle

100% Duty Cycle

Welding Current/Voltage Range

(Continuous)

50A/7V - 400A/37V

DC

Efficiency at 100% Load

78%

Idle Power

800W

INPUT - THREE PHASE ONLY

RATED OUTPUT

OUTPUT

MISC. INFORMATION

Height

Width

Depth

Weight

21.5 in.

19.5 in.

27.0 in.

(Lift bail, add 3.12 in)

300 lbs
(137 kg)

546 mm

495 mm

686 mm

(Lift bail, add 80 mm)

PHYSICAL DIMENSIONS