LN-7 SEQUENCE OF OPERATION (Optional Timer Kit not Installed)

Turn on Power Source

Closes 524-525

Closes 31-7A circuit

115V AC input power

is applied to SCR

control circuit and

Motor Armature

(539-541 circuit) is

energized

Energizes 1 CR

Press Gun Trigger

Closes 2-4 Circuit

Energizes welder

pilot relay

and/or

Energizes welder

contactor

Electrode now

“hot” to ground

Energizes aux. equipment

(gas solenoid) connected

to 7-32A with 115 VAC

Wire feed motor starts

at low speed and increases

speed to welding speed

Arc Starts

Welding

Release Gun Trigger

Opens 524-525

De-Energizes 1 CR

Opens 31-7A circuit

Disconnects motor

armature from SCR control.

1CR normally closed contact

closes shorting armature

thru dynamic braking

resistor.

Opens 2-4 Circuit

De-energizes welder

pilot relay

and/or

De-energizes welder

contactor

Electrode is

“cold” to work

Auxiliary equipment

de-energized

Wire feed motor stops

Unit ready for next weld