MAGNUM® 250 NR FM

CHART A

FM Adapter Kits

Product

FM Gun

To Be Used With

Number

Type

Wire Feeder

K489-1

K1614-12 & -13

LN7, Synergic 7, LN8, LN9

K489-2

K1614-12 & -13

LN25

K489-3

K1614-12 & -13

Miller

K489-4

K1614-12 & -13

Tweco adapted

K489-5

K1614-12 & -13

Hobart Series 2000

K489-6

K1614-12 & -13

L-Tec

K489-7

K1614-12 & -13

Lincoln -10 Series

APR97

CHART B

Contact Tips/

Part Number

English

Metric

Gas Less Diffuser

(Industry Ref.)

Wire Size

Wire Size

Standard Duty

S19391-1 (14-35)

.035”

0.9 mm

-8 (14-40)

.040”

1.0 mm

-2 (14-45)

.045”

1.2 mm

-3 (14-52)

.052”

1.3 mm

-4 (14-116)

1/16”

1.6 mm

Heavy Duty

S19392-1 (14H-35)

.035”

0.9 mm

-6 (14H-40)

.040”

1.0 mm

-2 (14H-45)

.045”

1.2 mm

-3 (14H-52)

.052”

1.3 mm

-4 (14H-116)

1/16”

1.6 mm

-8 (14AH-116)

.068” *

1.7 mm*

Tapered

S19393-1 (14T-35)

.035”

0.9 mm

-7 (14T-40)

.040”

1.0 mm

-2 (14T-45)

.045”

1.2 mm

-3 (14T-52)

.052”

1.3 mm

-4 (14T-116)

1/16”

1.6 mm

Gas less Diffuser

S24109-1

.035-.045”

0.9-1.2 mm

S24109-2

.052-.068”

1.3-1.7 mm

Nozzle Insulator

T12313

CHART C

Part Number

English

Metric

Cable Liner

(Industry Ref.)

Wire Size

Wire Size

For 15 ft (4.5 m)

M16087-5 (42-3035-15)

.030 - .035”

0.8-0.9 mm

and less

M16087-1 (42-4045-15)

.035 - .045”

0.9-1.2 mm

Trim to Fit

M18997-1

.052 - .068”

1.3-1.7 mm

(*)