Installation, Electrical installation, Safety precautions – Lincoln Electric IM629 Mobiflex 100-NF Portable Fan User Manual

Page 9: General description, Warning

Advertising
background image

K1668-2 Exhaust/Extension Set
Only qualified personnel should install, use or service
this equipment.

------------------------------------------------------------------------

ELECTRICAL INSTALLATION

Connect the inlet plug to 120VAC single phase,
grounded input suitable for 15 amp service.

INSTALLING THE HOSE/HOOD AND
EXHAUST/EXTENSION SETS

The hose and hood set and exhaust/extension set can
be connected to the fan and to each other using the
supplied hose clamps; refer to Figure 1 for possible
recommended configurations.

K1668-1 Hose and Hood Set includes:
(1) 6 in. diameter steel-reinforced hose, 16 ft. long

with magnet-mounted hood

(1) 6 in. hose clamp

K1668-2 Exhaust/Extension Set includes:
(1) 6 in. diameter steel-reinforced hose, 16 ft. long
(2) 6 in. hose clamps

Maximum recommended total hose length is
4 hoses (64 ft., 20 m), or 2 hoses (32 ft., 10m) on
each side of the fan.

Recommended configurations:

A

K1666-1 Mobiflex 100-NF Portable Fan

B

K1668-1 Hose and Hood Set

C

K1668-2 Exhaust/Extension Set

A

C

C

C

B

A

B

A

C

B

A

C

C

B

AIRFLOW

A-2

INSTALLATION

MOBIFLEX 100-NF PORTABLE FAN

A-2

Read this entire installation section before you
start installation.

SAFETY PRECAUTIONS

Do not attempt to use this equipment until you have
thoroughly read all installation, operating and mainte-
nance information supplied with your equipment. They
include important safety precautions and detailed
operating and maintenance instructions.

ELECTRIC SHOCK can kill.

Do not touch electrically live parts such
as internal wiring.

Turn the input power off at the fuse box
before working on this equipment.

Have a qualified person install and ser-
vice this equipment.

------------------------------------------------------------------------

MOVING PARTS can injure.

Do not operate with covers open or fil-
ter removed.

Keep away from moving parts.

------------------------------------------------------------------------

Only qualified personnel should install, use or service
this equipment.

GENERAL DESCRIPTION

The K1666-1 Mobiflex 100-NF Portable Fan provides
a portable low vacuum, high volume airflow for fume
extraction and ventilation applications. It is intended
for use in close or hard-to-reach spaces, on uneven or
multilevel ground, or any other situation (such as a
tank or small booth) requiring a small, lightweight,
highly portable fume extraction system without filtra-
tion. It comes with a 20 ft. cord to connect to 120VAC,
1ph, 60Hz supply, and a Start/Stop switch.

The portable fan should be used with the K1668-1
Hose and Hood Set, which consists of a 6in, 16ft.
long, steel-reinforced flexible hose and a magnet-
mounted hood. The K1668-2 Exhaust/Extension set is
a 16ft. connection hose that can be used to extend the
inlet side of the extraction system, and/or installed on
the exhaust side of the fan to run exhaust further from
the inlet.

Equipment covered by this manual:
K1666-1 Mobiflex 100-NF Portable Fan
K1668-1 Hose and Hood Set

WARNING

WARNING

Advertising