Operation, Dc wire feed welding (cv) with ranger 300d, Carbon arc gouging (constant current) – Lincoln Electric IM571 RANGER 300 D and 300 DLX User Manual

Page 25: B-10

Advertising
background image

B-10

OPERATION

B-10

DC WIRE FEED WELDING (CV)
WITH RANGER 300D

1. Connect an LN-25 with internal contactor to the

Ranger 300D.

2. The only Innershield electrode recommended for

use with the Ranger 300D is NR211MP. The elec-
trode sizes and welding ranges that can be used
with the Ranger 300D are shown in the following
table:

The Ranger 300 D is recommended for limited "MIG"
welding (GMAW - gas metal arc welding). The recom-
mended electrodes are .030 and .035 L-50 and L-56.
They must be used with a blended shielding gas such
as C25 (75% Argon - 25% CO2). The .035 diameter
electrode gives improved starting compared to .030
diameter. The welding ranges that can be used with
the Ranger 300D are shown in the following table:

3. Set the IDLER control to AUTO.

4. Set the RANGER switch to the WIRE FEED (CV-

red setting).

5. Set the POLARITY SWITCH to either WIRE FEED

DC+ (red) or WIRE FEED DC- (red), depending on
the electrode.

6. Set the OUTPUT control to a setting between 1

and 10 that gives the most stable arc for the appli-
cation.

7. Strike an arc and begin welding. the OUTPUT

control can be adjusted while welding.

DO NOT

change the RANGE switch setting while welding.
This can result in damage to the switch.

AFTER YOU FINISH WELDING:

1. Stop the engine

2. Allow the work to cool completely

3. Remove the work clamp from the work

CARBON ARC GOUGING
(CONSTANT CURRENT)

1. The recommended electrode ia a 3/16” (4.8 mm)

dia. carbon

2. Set the RANGE switch to 300

3. Set the POLARITY switch to DC+ (cc - blue setting)

4. Set the OUTPUT control to 10

5. Strike an arc and begin gouging

After you finish gouging:

1. Stop the engine

2. Allow the electrode and work to cool completely

3. Remove the work clamp from the work

RANGER 300 D AND 300 DLX

Electrode

Diameter

Wire Speed

in. / min.

Approximate

Current Range

.035”

.045”

.068”

70 - 110

70 - 130

40 - 90

60 - 120 amps

120 - 170 amps

125 - 210 amps

Electrode

Diameter

Wire Speed

in. / min.

Approximate

Current Range

.030”

.035”

150 - 450

100 - 350

80 - 170 amps

80 - 190 amps

Advertising