TROUBLESHOOTING

D-4

PLASMA TORCH

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local
Lincoln Authorized Field Service Facility
for technical troubleshooting assistance before you proceed.

CAUTION

FUNCTION PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE CAUSE

RECOMMENDED

COURSE OF ACTION

Only a brief spurt of a Pilot Arc

appears

f. Pro-Cut inoperative.

a. Make sure the air pressure is set

correctly

b. Air flow may be restricted.

c. There may be oil in the air.

d. The Pro-Cut is not working prop-

erly.

f. Refer to the troubleshooting

guide for the Pro-Cut.

a. Press the Purge button on the

Pro-Cut and adjust the air pres-

sure to 70 psi while the air is

flowing.

b. Check air connection to the Pro-

Cut as well as the torch connec-

tion for any blockage of air flow.

c. Check the air filter for oil.

Replace if necessary and elimi-

nate the source of oil.

d. Refer to the troubleshooting

guide for the Pro-Cut.