Installation, Technical specifications – power feed 11 – Lincoln Electric IM613 POWER FEED 11 SemiAutomatic Cabinet WIRE FEEDER User Manual

Page 9

Advertising
background image

A-1

INSTALLATION

POWER FEED 11

A-1

TECHNICAL SPECIFICATIONS – Power Feed 11

COMPLETE UNITS

SPEC.#

TYPE

LOW SPEED RATIO

HIGH SPEED RATIO

The PF-11 is environmentally rated IP21S per IEC60529

Wire Size

Wire Size

Speed

Solid

Cored

Speed

Solid

Cored

K1635-1 Power Feed 11

50-625 IPM

.025 - 1/16 in.

.030 - 5/64 in

75 - 1100 IPM

.025 - .045 in.

.030 - .045 in.

Cabinet

(1.27-15.9 m/m)

(0.6 - 1.6 mm)

(0.8 - 2.0 mm)

(2.03 - 27.9 m/m)

(0.6 - 1.2 mm)

(0.8 - 1.2 mm)

Wire
Feeder
(World Model)

K1636-1 Power Feed 11

50-625 IPM

.025 - 1/16 in.

.035 - 5/64 in

75 - 1100 IPM

.025 - .045 in.

.035 - .045 in.

Cabinet

(1.27-15.9 m/m)

(0.6 - 1.6 mm)

(0.9 - 2.0 mm)

(2.03 - 27.9 m/m)

(0.6 - 1.2 mm)

(0.9 - 1.2 mm)

Wire
Feeder
(European
Model)

COMPLETE UNITS

SPEC.#

TYPE

INPUT POWER

PHYSICAL SIZE•

TEMPERATURE RATING

Dimensions

Height

Width

Depth

Weight

Operating

Storage

K1635-1

Power

40 VDC

20.0 “ 9.0

28.7 “

61 Lbs

Feed 11

(508 mm)

( 230 mm)

(729 mm)

(27.7 Kg)

(World
Model)

+40°C

+40°C

to

to

K1636-1

Power 40

VDC

20.0

“ 9.0

28.7 “

61 Lbs

-20°C

-40°C

Feed 11

(508 mm)

( 230 mm)

(729 mm)

(27.7 Kg)

(European
Model)

Advertising