Installation, Rated output - welder, Output - welder and generator – Lincoln Electric IM560 POWER-ARC 5000 User Manual
Page 8: Physical dimensions

A-1
INSTALLATION
POWER ARC 5000
A-1
TECHNICAL SPECIFICATIONS - POWER ARC 5000
INPUT - GASOLINE ENGINE
Manufacturer Description
Speed
Displacement
Ignition
Capacities
Briggs &
1 cyl.,
3700 RPM
24.4 cu. in.
Electronic
Fuel: 5.5 gal. (20.8 l)
Stratton
4 cycle
± 50 RPM
(400 cc)
Ignition;
Industrial
air-cooled
at no load
Recoil start;
Oil: 1.5 qt. (1.42 l)
Plus
gasoline
Manual choke
11 HP @
3600 RPM
RATED OUTPUT - WELDER
Duty Cycle
Amps
Volts at Rated Amperes
40% Duty Cycle
150
25 VAC
60% Duty Cycle
125
25 VAC
OUTPUT - WELDER AND GENERATOR
Welding Ranges
Welder Open Circuit Voltage
AC Auxiliary Power
70 - 150 Amps
62 VAC Max.
5000 Watts 41.6/20.8 amps
120/240 volts, +5%, -15%
PHYSICAL DIMENSIONS
Height
Width
Depth
Weight
26.62 in.
20 in.
29 in.
208 lb. - 215 lb w/ undercarriage
676 mm
508 mm
737 mm
94.3 kg. - 97.5 kg. w/ undercarriage